Boxes

plc-kfe-gatt

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-kfe-gatt

ID

2

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001ce4006400010003000000000000000000001c64010000

SyncMan

008ee7002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

12

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1801

BIT

None

1

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

64

#x10f4

ULINT

External time stamp

64

#x10f4

ULINT

None

32

ARRAY [0..3] OF BYTE

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

32

#x10f4

UDINT

External time stamp

32

#x10f4

UDINT

None

32

ARRAY [0..3] OF BYTE

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

16

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

Current Transmission

#x6000

ST_PMPS_Attenuator_IO

bGattStatus

#x6000

BYTE

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

Requested Transmission

#x7000

ST_PMPS_Attenuator_IO

CurrentBP

#x7000

ST_BeamParams_IO

E0 (EK1200)

EtherCAT
Basic Settings

Name

Data

Name

E0 (EK1200)

ID

5

FFO

EtherCAT (2 PDOs)
Basic Settings

Name

Data

Name

FFO

ID

8

SyncMan

000f01004400010003000000000000000000000f44090000

Fmmu

0000000000000000000f00020100000001000000060000000000000000000000

PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7000

BIT

TriState

#x7000

BIT

PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7010

BIT

TriState

#x7010

BIT

PMPS_Premp

EtherCAT (16 PDOs)
Basic Settings

Name

Data

Name

PMPS_Premp

ID

9

SyncMan

000f01004400010003000000000000000100000f44090000

SyncMan

010f01004400010003000000000000000100010f44090000

Fmmu

0000000000000000000f00020100000001000000000000000000000000000000

PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7000

BIT

PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7010

BIT

PDO Channel 3 (Index #x1602, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7020

BIT

PDO Channel 4 (Index #x1603, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7030

BIT

PDO Channel 5 (Index #x1604, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7040

BIT

PDO Channel 6 (Index #x1605, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7050

BIT

PDO Channel 7 (Index #x1606, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7060

BIT

PDO Channel 8 (Index #x1607, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7070

BIT

PDO Channel 9 (Index #x1608, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x7080

BIT

PDO Channel 10 (Index #x1609, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x7090

BIT

PDO Channel 11 (Index #x160a, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70a0

BIT

PDO Channel 12 (Index #x160b, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

ST3K4 RELAY IN

#x70b0

BIT

PDO Channel 13 (Index #x160c, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

MR1K1 IN

#x70c0

BIT

PDO Channel 14 (Index #x160d, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

ST1K2 RELAY IN

#x70d0

BIT

PDO Channel 15 (Index #x160e, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70e0

BIT

PDO Channel 16 (Index #x160f, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70f0

BIT

E3 (EK1122)

EtherCAT
Basic Settings

Name

Data

Name

E3 (EK1122)

ID

12

950-101W-R4-MPS-2

EtherCAT
Basic Settings

Name

Data

Name

950-101W-R4-MPS-2

ID

13

PPS Stoppers 1

EtherCAT (8 PDOs)
Basic Settings

Name

Data

Name

PPS Stoppers 1

ID

14

SyncMan

001001000000010004000000000000000100001000010000

Fmmu

0000000000000000001000010100000002000000000000000000000000000000

PDO Channel 1 (Index #x1a00, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST3K4 IN

#x6000

BIT

PDO Channel 2 (Index #x1a01, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST3K4 OUT

#x6010

BIT

PDO Channel 3 (Index #x1a02, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1K2 IN

#x6020

BIT

PDO Channel 4 (Index #x1a03, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1K2 OUT

#x6030

BIT

PDO Channel 5 (Index #x1a04, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6040

BIT

PDO Channel 6 (Index #x1a05, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6050

BIT

PDO Channel 7 (Index #x1a06, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6060

BIT

PDO Channel 8 (Index #x1a07, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6070

BIT

PPS Stoppers 2

EtherCAT (8 PDOs)
Basic Settings

Name

Data

Name

PPS Stoppers 2

ID

15

SyncMan

001001000000010004000000000000000100001000010000

Fmmu

0000000000000000001000010100000002000000000000000000000000000000

PDO Channel 1 (Index #x1a00, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6000

BIT

PDO Channel 2 (Index #x1a01, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6010

BIT

PDO Channel 3 (Index #x1a02, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6020

BIT

PDO Channel 4 (Index #x1a03, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6030

BIT

PDO Channel 5 (Index #x1a04, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6040

BIT

PDO Channel 6 (Index #x1a05, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6050

BIT

PDO Channel 7 (Index #x1a06, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6060

BIT

PDO Channel 8 (Index #x1a07, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6070

BIT

plc-kfe-motion

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-kfe-motion

ID

19

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001c8c016400010003000000000000000000001c64010000

SyncMan

008e8e012000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

AptArrayStatus

#x6000

ARRAY [1..4] OF ST_PMPS_Aperture_IO

SattArrayStatus

#x6000

ARRAY [1..16] OF ST_PMPS_Attenuator_IO

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

AptArrayReq

#x7000

ARRAY [1..4] OF ST_PMPS_Aperture_IO

SattArrayReq

#x7000

ARRAY [1..16] OF ST_PMPS_Attenuator_IO

CurrentBP

#x7000

ST_BeamParams_IO

plc-kfe-gmd-vac-01

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-kfe-gmd-vac-01

ID

20

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cd4006400010003000000000000000000001c64010000

SyncMan

008ed6002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-kfe-xgmd-vac-01

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-kfe-xgmd-vac-01

ID

21

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cd4006400010003000000000000000000001c64010000

SyncMan

008ed6002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

Term 22 (EK1110)

EtherCAT
Basic Settings

Name

Data

Name

Term 22 (EK1110)

ID

22

B940-009-R07-MPS-1 CU1-ESC1

EtherCAT
Basic Settings

Name

Data

Name

B940-009-R07-MPS-1 CU1-ESC1

ID

23

B940-009-R07-MPS-1 CU1-ESC2

EtherCAT
Basic Settings

Name

Data

Name

B940-009-R07-MPS-1 CU1-ESC2

ID

28

B940-009-R07-MPS-1 CU1-ESC3

EtherCAT
Basic Settings

Name

Data

Name

B940-009-R07-MPS-1 CU1-ESC3

ID

29

950-101W-R4-MPS-2-E3 (EL9011)

EtherCAT
Basic Settings

Name

Data

Name

950-101W-R4-MPS-2-E3 (EL9011)

ID

30

plc-kfe-vac

EtherCAT (5 PDOs)
Basic Settings

Name

Data

Name

plc-kfe-vac

ID

32

SyncMan

001000012600010001000000800000040001001026010000

SyncMan

001400012200010002000000800000040001001422010000

SyncMan

0018dc002400010003000000000000000000001824010000

SyncMan

001ede002000010004000000000000000200001e20010000

Fmmu

0000000000000000001800020100000001000000000000000000000000000000

Fmmu

0000000000000000001e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-tmo-mot

EtherCAT (5 PDOs)
Basic Settings

Name

Data

Name

plc-tmo-mot

ID

34

SyncMan

001000012600010001000000800000040001001026010000

SyncMan

001400012200010002000000800000040001001422010000

SyncMan

0018dc002400010003000000000000000000001824010000

SyncMan

001ee0002000010004000000000000000200001e20010000

Fmmu

0000000000000000001800020100000001000000000000000000000000000000

Fmmu

0000000000000000001e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)

Name

Comment

BitLen

Index

Type

bST4K4_IN

#x6000

BOOL

bST4K4_OUT

#x6000

BOOL

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-tmo-optics

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-tmo-optics

ID

35

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ede002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-tmo-vac

EtherCAT (5 PDOs)
Basic Settings

Name

Data

Name

plc-tmo-vac

ID

36

SyncMan

001000012600010001000000800000040001001026010000

SyncMan

001400012200010002000000800000040001001422010000

SyncMan

0018dc002400010003000000000000000000001824010000

SyncMan

001ede002000010004000000000000000200001e20010000

Fmmu

0000000000000000001800020100000001000000000000000000000000000000

Fmmu

0000000000000000001e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-rix-mot

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-rix-mot

ID

38

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001c5c016400010003000000000000000000001c64010000

SyncMan

008e5e012000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

12

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1801

BIT

None

1

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

64

#x10f4

ULINT

External time stamp

64

#x10f4

ULINT

None

32

ARRAY [0..3] OF BYTE

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

32

#x10f4

UDINT

External time stamp

32

#x10f4

UDINT

None

32

ARRAY [0..3] OF BYTE

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

16

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

SattArrayStatus

#x6000

ARRAY [1..16] OF ST_PMPS_Attenuator_IO

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

SattArrayReq

#x7000

ARRAY [1..16] OF ST_PMPS_Attenuator_IO

CurrentBP

#x7000

ST_BeamParams_IO

plc-rix-vac

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-rix-vac

ID

39

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ede002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-rix-optics

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-rix-optics

ID

40

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ee2002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

MR1K1_Y_ENC

#x6000

UDINT

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-crix-vac

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-crix-vac

ID

45

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ede002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-crix-mot

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-crix-mot

ID

47

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ede002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

12

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1801

BIT

None

1

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

64

#x10f4

ULINT

External time stamp

64

#x10f4

ULINT

None

32

ARRAY [0..3] OF BYTE

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

32

#x10f4

UDINT

External time stamp

32

#x10f4

UDINT

None

32

ARRAY [0..3] OF BYTE

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

16

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-qrix-vac

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-qrix-vac

ID

50

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008edf002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

FFO

#x6000

BOOL

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-qrix-mot

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-qrix-mot

ID

51

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001c00006400000003000000000000000000001c64010000

SyncMan

008e02002000010004000000000000000200008e20010000

Fmmu

0000000000000000000000020000000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO