Boxes
plc-kfe-gatt
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-kfe-gatt | 
| ID | 2 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001ce4006400010003000000000000000000001c64010000 | 
| SyncMan | 008ee7002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | 12 | ARRAY [0..11] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1801 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1801 | BIT | 
| None | 1 | ARRAY [0..0] OF BIT | ||
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | 2 | #x10f4 | BIT2 | 
| None | 10 | ARRAY [0..9] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1802 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1802 | BIT | 
| Timestamp update toggle | Bit toggles when new timestamp data available | 1 | #x10f4 | BIT | 
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
| Internal time stamp | 64 | #x10f4 | ULINT | |
| External time stamp | 64 | #x10f4 | ULINT | |
| None | 32 | ARRAY [0..3] OF BYTE | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | 2 | #x10f4 | BIT2 | 
| None | 10 | ARRAY [0..9] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1803 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1803 | BIT | 
| Timestamp update toggle | Bit toggles when new timestamp data available | 1 | #x10f4 | BIT | 
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
| Internal time stamp | 32 | #x10f4 | UDINT | |
| External time stamp | 32 | #x10f4 | UDINT | |
| None | 32 | ARRAY [0..3] OF BYTE | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | 16 | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Current Transmission | #x6000 | ST_PMPS_Attenuator_IO | ||
| bGattStatus | #x6000 | BYTE | ||
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Requested Transmission | #x7000 | ST_PMPS_Attenuator_IO | ||
| CurrentBP | #x7000 | ST_BeamParams_IO | 
E0 (EK1200)
EtherCAT
| Name | Data | 
|---|---|
| Name | E0 (EK1200) | 
| ID | 5 | 
FFO
EtherCAT (2 PDOs)
| Name | Data | 
|---|---|
| Name | FFO | 
| ID | 8 | 
| SyncMan | 000f01004400010003000000000000000000000f44090000 | 
| Fmmu | 0000000000000000000f00020100000001000000060000000000000000000000 | 
PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7000 | BIT | ||
| TriState | #x7000 | BIT | 
PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7010 | BIT | ||
| TriState | #x7010 | BIT | 
PMPS_Premp
EtherCAT (16 PDOs)
| Name | Data | 
|---|---|
| Name | PMPS_Premp | 
| ID | 9 | 
| SyncMan | 000f01004400010003000000000000000100000f44090000 | 
| SyncMan | 010f01004400010003000000000000000100010f44090000 | 
| Fmmu | 0000000000000000000f00020100000001000000000000000000000000000000 | 
PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7000 | BIT | 
PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7010 | BIT | 
PDO Channel 3 (Index #x1602, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7020 | BIT | 
PDO Channel 4 (Index #x1603, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7030 | BIT | 
PDO Channel 5 (Index #x1604, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7040 | BIT | 
PDO Channel 6 (Index #x1605, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7050 | BIT | 
PDO Channel 7 (Index #x1606, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7060 | BIT | 
PDO Channel 8 (Index #x1607, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7070 | BIT | 
PDO Channel 9 (Index #x1608, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7080 | BIT | 
PDO Channel 10 (Index #x1609, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x7090 | BIT | 
PDO Channel 11 (Index #x160a, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x70a0 | BIT | 
PDO Channel 12 (Index #x160b, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| ST3K4 RELAY IN | #x70b0 | BIT | 
PDO Channel 13 (Index #x160c, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| MR1K1 IN | #x70c0 | BIT | 
PDO Channel 14 (Index #x160d, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| ST1K2 RELAY IN | #x70d0 | BIT | 
PDO Channel 15 (Index #x160e, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x70e0 | BIT | 
PDO Channel 16 (Index #x160f, Flags #x0011, SyncMan 1)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Output | #x70f0 | BIT | 
E3 (EK1122)
EtherCAT
| Name | Data | 
|---|---|
| Name | E3 (EK1122) | 
| ID | 12 | 
950-101W-R4-MPS-2
EtherCAT
| Name | Data | 
|---|---|
| Name | 950-101W-R4-MPS-2 | 
| ID | 13 | 
PPS Stoppers 1
EtherCAT (8 PDOs)
| Name | Data | 
|---|---|
| Name | PPS Stoppers 1 | 
| ID | 14 | 
| SyncMan | 001001000000010004000000000000000100001000010000 | 
| Fmmu | 0000000000000000001000010100000002000000000000000000000000000000 | 
PDO Channel 1 (Index #x1a00, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| ST3K4 IN | #x6000 | BIT | 
PDO Channel 2 (Index #x1a01, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| ST3K4 OUT | #x6010 | BIT | 
PDO Channel 3 (Index #x1a02, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| ST1K2 IN | #x6020 | BIT | 
PDO Channel 4 (Index #x1a03, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| ST1K2 OUT | #x6030 | BIT | 
PDO Channel 5 (Index #x1a04, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6040 | BIT | 
PDO Channel 6 (Index #x1a05, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6050 | BIT | 
PDO Channel 7 (Index #x1a06, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6060 | BIT | 
PDO Channel 8 (Index #x1a07, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6070 | BIT | 
PPS Stoppers 2
EtherCAT (8 PDOs)
| Name | Data | 
|---|---|
| Name | PPS Stoppers 2 | 
| ID | 15 | 
| SyncMan | 001001000000010004000000000000000100001000010000 | 
| Fmmu | 0000000000000000001000010100000002000000000000000000000000000000 | 
PDO Channel 1 (Index #x1a00, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6000 | BIT | 
PDO Channel 2 (Index #x1a01, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6010 | BIT | 
PDO Channel 3 (Index #x1a02, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6020 | BIT | 
PDO Channel 4 (Index #x1a03, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6030 | BIT | 
PDO Channel 5 (Index #x1a04, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6040 | BIT | 
PDO Channel 6 (Index #x1a05, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6050 | BIT | 
PDO Channel 7 (Index #x1a06, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6060 | BIT | 
PDO Channel 8 (Index #x1a07, Flags #x0011, SyncMan 0)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Input | #x6070 | BIT | 
plc-kfe-motion
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-kfe-motion | 
| ID | 19 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001c8c016400010003000000000000000000001c64010000 | 
| SyncMan | 008e8e012000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| AptArrayStatus | #x6000 | ARRAY [1..4] OF ST_PMPS_Aperture_IO | ||
| SattArrayStatus | #x6000 | ARRAY [1..16] OF ST_PMPS_Attenuator_IO | ||
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| AptArrayReq | #x7000 | ARRAY [1..4] OF ST_PMPS_Aperture_IO | ||
| SattArrayReq | #x7000 | ARRAY [1..16] OF ST_PMPS_Attenuator_IO | ||
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-kfe-gmd-vac-01
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-kfe-gmd-vac-01 | 
| ID | 20 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cd4006400010003000000000000000000001c64010000 | 
| SyncMan | 008ed6002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-kfe-xgmd-vac-01
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-kfe-xgmd-vac-01 | 
| ID | 21 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cd4006400010003000000000000000000001c64010000 | 
| SyncMan | 008ed6002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
Term 22 (EK1110)
EtherCAT
| Name | Data | 
|---|---|
| Name | Term 22 (EK1110) | 
| ID | 22 | 
B940-009-R07-MPS-1 CU1-ESC1
EtherCAT
| Name | Data | 
|---|---|
| Name | B940-009-R07-MPS-1 CU1-ESC1 | 
| ID | 23 | 
B940-009-R07-MPS-1 CU1-ESC2
EtherCAT
| Name | Data | 
|---|---|
| Name | B940-009-R07-MPS-1 CU1-ESC2 | 
| ID | 28 | 
B940-009-R07-MPS-1 CU1-ESC3
EtherCAT
| Name | Data | 
|---|---|
| Name | B940-009-R07-MPS-1 CU1-ESC3 | 
| ID | 29 | 
950-101W-R4-MPS-2-E3 (EL9011)
EtherCAT
| Name | Data | 
|---|---|
| Name | 950-101W-R4-MPS-2-E3 (EL9011) | 
| ID | 30 | 
plc-kfe-vac
EtherCAT (5 PDOs)
| Name | Data | 
|---|---|
| Name | plc-kfe-vac | 
| ID | 32 | 
| SyncMan | 001000012600010001000000800000040001001026010000 | 
| SyncMan | 001400012200010002000000800000040001001422010000 | 
| SyncMan | 0018dc002400010003000000000000000000001824010000 | 
| SyncMan | 001ede002000010004000000000000000200001e20010000 | 
| Fmmu | 0000000000000000001800020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000001e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| Control Value for DC Master Clock | #x10f4 | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| Control Value for DC Master Clock | #x10f4 | UDINT | 
PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-tmo-mot
EtherCAT (5 PDOs)
| Name | Data | 
|---|---|
| Name | plc-tmo-mot | 
| ID | 34 | 
| SyncMan | 001000012600010001000000800000040001001026010000 | 
| SyncMan | 001400012200010002000000800000040001001422010000 | 
| SyncMan | 0018dc002400010003000000000000000000001824010000 | 
| SyncMan | 001ee0002000010004000000000000000200001e20010000 | 
| Fmmu | 0000000000000000001800020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000001e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| Control Value for DC Master Clock | #x10f4 | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| Control Value for DC Master Clock | #x10f4 | UDINT | 
PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| bST4K4_IN | #x6000 | BOOL | ||
| bST4K4_OUT | #x6000 | BOOL | ||
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-tmo-optics
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-tmo-optics | 
| ID | 35 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cdc006400010003000000000000000000001c64010000 | 
| SyncMan | 008ede002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-tmo-vac
EtherCAT (5 PDOs)
| Name | Data | 
|---|---|
| Name | plc-tmo-vac | 
| ID | 36 | 
| SyncMan | 001000012600010001000000800000040001001026010000 | 
| SyncMan | 001400012200010002000000800000040001001422010000 | 
| SyncMan | 0018dc002400010003000000000000000000001824010000 | 
| SyncMan | 001ede002000010004000000000000000200001e20010000 | 
| Fmmu | 0000000000000000001800020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000001e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| Control Value for DC Master Clock | #x10f4 | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..5] OF BIT | |||
| None | ARRAY [0..2] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1800 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1800 | BIT | |
| Control value update toggle | Bit toggles when new DC control data available | #x10f4 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| Control Value for DC Master Clock | #x10f4 | UDINT | 
PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-rix-mot
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-rix-mot | 
| ID | 38 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001c5c016400010003000000000000000000001c64010000 | 
| SyncMan | 008e5e012000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | 12 | ARRAY [0..11] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1801 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1801 | BIT | 
| None | 1 | ARRAY [0..0] OF BIT | ||
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | 2 | #x10f4 | BIT2 | 
| None | 10 | ARRAY [0..9] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1802 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1802 | BIT | 
| Timestamp update toggle | Bit toggles when new timestamp data available | 1 | #x10f4 | BIT | 
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
| Internal time stamp | 64 | #x10f4 | ULINT | |
| External time stamp | 64 | #x10f4 | ULINT | |
| None | 32 | ARRAY [0..3] OF BYTE | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | 2 | #x10f4 | BIT2 | 
| None | 10 | ARRAY [0..9] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1803 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1803 | BIT | 
| Timestamp update toggle | Bit toggles when new timestamp data available | 1 | #x10f4 | BIT | 
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
| Internal time stamp | 32 | #x10f4 | UDINT | |
| External time stamp | 32 | #x10f4 | UDINT | |
| None | 32 | ARRAY [0..3] OF BYTE | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | 16 | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| SattArrayStatus | #x6000 | ARRAY [1..16] OF ST_PMPS_Attenuator_IO | ||
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| SattArrayReq | #x7000 | ARRAY [1..16] OF ST_PMPS_Attenuator_IO | ||
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-rix-vac
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-rix-vac | 
| ID | 39 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cdc006400010003000000000000000000001c64010000 | 
| SyncMan | 008ede002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-rix-optics
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-rix-optics | 
| ID | 40 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cdc006400010003000000000000000000001c64010000 | 
| SyncMan | 008ee2002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| MR1K1_Y_ENC | #x6000 | UDINT | ||
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-crix-vac
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-crix-vac | 
| ID | 45 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cdc006400010003000000000000000000001c64010000 | 
| SyncMan | 008ede002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-crix-mot
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-crix-mot | 
| ID | 47 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cdc006400010003000000000000000000001c64010000 | 
| SyncMan | 008ede002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | 12 | ARRAY [0..11] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1801 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1801 | BIT | 
| None | 1 | ARRAY [0..0] OF BIT | ||
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | 2 | #x10f4 | BIT2 | 
| None | 10 | ARRAY [0..9] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1802 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1802 | BIT | 
| Timestamp update toggle | Bit toggles when new timestamp data available | 1 | #x10f4 | BIT | 
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
| Internal time stamp | 64 | #x10f4 | ULINT | |
| External time stamp | 64 | #x10f4 | ULINT | |
| None | 32 | ARRAY [0..3] OF BYTE | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | 2 | #x10f4 | BIT2 | 
| None | 10 | ARRAY [0..9] OF BIT | ||
| TxPDO toggle | Bit toggles when new data from other side received | 1 | #x1803 | BIT | 
| TxPDO state | 0: Other side is in OP state >0: Error | 1 | #x1803 | BIT | 
| Timestamp update toggle | Bit toggles when new timestamp data available | 1 | #x10f4 | BIT | 
| External device not connected | 0: External device connected 1: External device not connected | 1 | #x10f4 | BIT | 
| Internal time stamp | 32 | #x10f4 | UDINT | |
| External time stamp | 32 | #x10f4 | UDINT | |
| None | 32 | ARRAY [0..3] OF BYTE | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | 16 | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-qrix-vac
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-qrix-vac | 
| ID | 50 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001cdc006400010003000000000000000000001c64010000 | 
| SyncMan | 008edf002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000001c00020100000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | ||
| FFO | #x6000 | BOOL | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO | 
plc-qrix-mot
EtherCAT (6 PDOs)
| Name | Data | 
|---|---|
| Name | plc-qrix-mot | 
| ID | 51 | 
| BootStrapData | 0010140200141402 | 
| SyncMan | 0010000426000100010000008000da050004001026010000 | 
| SyncMan | 0016000422000100020000008000da050004001622010000 | 
| SyncMan | 001c00006400000003000000000000000000001c64010000 | 
| SyncMan | 008e02002000010004000000000000000200008e20010000 | 
| Fmmu | 0000000000000000000000020000000001000000000000000000000000000000 | 
| Fmmu | 0000000000000000008e00010100000002000000000000000000000000000000 | 
| Fmmu | 00000000000000000d0800010100000003000000000000000000000000000000 | 
| CoeProfile | 5001 | 
PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| None | ARRAY [0..11] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1801 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1801 | BIT | |
| None | ARRAY [0..0] OF BIT | |||
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | 
PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1802 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1802 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | ULINT | ||
| External time stamp | #x10f4 | ULINT | ||
| None | UDINT | 
PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Sync Mode | 0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master | #x10f4 | BIT2 | |
| None | ARRAY [0..9] OF BIT | |||
| TxPDO toggle | Bit toggles when new data from other side received | #x1803 | BIT | |
| TxPDO state | 0: Other side is in OP state >0: Error | #x1803 | BIT | |
| Timestamp update toggle | Bit toggles when new timestamp data available | #x10f4 | BIT | |
| External device not connected | 0: External device connected 1: External device not connected | #x10f4 | BIT | |
| Internal time stamp | #x10f4 | UDINT | ||
| External time stamp | #x10f4 | UDINT | ||
| None | UDINT | 
PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| Data Bytes Pending | #xf650 | UINT | 
PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| RequestedBP | #x6000 | ST_BeamParams_IO | 
PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)
| Name | Comment | BitLen | Index | Type | 
|---|---|---|---|---|
| CurrentBP | #x7000 | ST_BeamParams_IO |