Boxes

plc-xrt-homs

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-xrt-homs

ID

1

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ede002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-lfe-motion

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-lfe-motion

ID

2

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001c5c016400010003000000000000000000001c64010000

SyncMan

008e5e012000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

12

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1801

BIT

None

1

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

64

#x10f4

ULINT

External time stamp

64

#x10f4

ULINT

None

32

ARRAY [0..3] OF BYTE

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

32

#x10f4

UDINT

External time stamp

32

#x10f4

UDINT

None

32

ARRAY [0..3] OF BYTE

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

16

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

SattArrayStatus

#x6000

ARRAY [1..16] OF ST_PMPS_Attenuator_IO

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

SattArrayReq

#x7000

ARRAY [1..16] OF ST_PMPS_Attenuator_IO

CurrentBP

#x7000

ST_BeamParams_IO

Term 12 (EK1200)

EtherCAT
Basic Settings

Name

Data

Name

Term 12 (EK1200)

ID

5

FFO

EtherCAT (2 PDOs)
Basic Settings

Name

Data

Name

FFO

ID

8

SyncMan

000f01004400010003000000000000000000000f44090000

Fmmu

0000000000000000000f00020100000001000000060000000000000000000000

PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7000

BIT

TriState

#x7000

BIT

PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7010

BIT

TriState

#x7010

BIT

PMPS_Premp

EtherCAT (16 PDOs)
Basic Settings

Name

Data

Name

PMPS_Premp

ID

9

SyncMan

000f01004400010003000000000000000100000f44090000

SyncMan

010f01004400010003000000000000000100010f44090000

Fmmu

0000000000000000000f00020100000001000000000000000000000000000000

PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7000

BIT

PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7010

BIT

PDO Channel 3 (Index #x1602, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7020

BIT

PDO Channel 4 (Index #x1603, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7030

BIT

PDO Channel 5 (Index #x1604, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7040

BIT

PDO Channel 6 (Index #x1605, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7050

BIT

PDO Channel 7 (Index #x1606, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7060

BIT

PDO Channel 8 (Index #x1607, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7070

BIT

PDO Channel 9 (Index #x1608, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x7080

BIT

PDO Channel 10 (Index #x1609, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x7090

BIT

PDO Channel 11 (Index #x160a, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70a0

BIT

PDO Channel 12 (Index #x160b, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70b0

BIT

PDO Channel 13 (Index #x160c, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70c0

BIT

PDO Channel 14 (Index #x160d, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70d0

BIT

PDO Channel 15 (Index #x160e, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70e0

BIT

PDO Channel 16 (Index #x160f, Flags #x0011, SyncMan 1)

Name

Comment

BitLen

Index

Type

Output

#x70f0

BIT

E3 (EK1122)

EtherCAT
Basic Settings

Name

Data

Name

E3 (EK1122)

ID

12

950-101W-R4-MPS-1

EtherCAT
Basic Settings

Name

Data

Name

950-101W-R4-MPS-1

ID

13

PPS_Stoppers

EtherCAT (8 PDOs)
Basic Settings

Name

Data

Name

PPS_Stoppers

ID

14

SyncMan

001001000000010004000000000000000100001000010000

Fmmu

0000000000000000001000010100000002000000000000000000000000000000

PDO Channel 1 (Index #x1a00, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1L0_PPS_IN

#x6000

BIT

PDO Channel 2 (Index #x1a01, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1L0_PPS_OUT

#x6010

BIT

PDO Channel 3 (Index #x1a02, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1L1_PPS_IN

#x6020

BIT

PDO Channel 4 (Index #x1a03, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1L1_PPS_OUT

#x6030

BIT

PDO Channel 5 (Index #x1a04, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6040

BIT

PDO Channel 6 (Index #x1a05, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6050

BIT

PDO Channel 7 (Index #x1a06, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6060

BIT

PDO Channel 8 (Index #x1a07, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6070

BIT

Term 15 (EL1008)

EtherCAT (8 PDOs)
Basic Settings

Name

Data

Name

Term 15 (EL1008)

ID

15

SyncMan

001001000000010004000000000000000100001000010000

Fmmu

0000000000000000001000010100000002000000000000000000000000000000

PDO Channel 1 (Index #x1a00, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6000

BIT

PDO Channel 2 (Index #x1a01, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6010

BIT

PDO Channel 3 (Index #x1a02, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6020

BIT

PDO Channel 4 (Index #x1a03, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6030

BIT

PDO Channel 5 (Index #x1a04, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6040

BIT

PDO Channel 6 (Index #x1a05, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6050

BIT

PDO Channel 7 (Index #x1a06, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6060

BIT

PDO Channel 8 (Index #x1a07, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Input

#x6070

BIT

MPS_Relay

EtherCAT (4 PDOs)
Basic Settings

Name

Data

Name

MPS_Relay

ID

16

SyncMan

000f01004400010003000000000000000000000f44090000

Fmmu

0000000000000000000f00020100000001000000000000000000000000000000

PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1L0_RELAY_OUT

#x7000

BIT

PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

ST1L0_RELAY_IN

#x7010

BIT

PDO Channel 3 (Index #x1602, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7020

BIT

PDO Channel 4 (Index #x1603, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7030

BIT

Term 17 (EL2004)

EtherCAT (4 PDOs)
Basic Settings

Name

Data

Name

Term 17 (EL2004)

ID

17

SyncMan

000f01004400010003000000000000000000000f44090000

Fmmu

0000000000000000000f00020100000001000000000000000000000000000000

PDO Channel 1 (Index #x1600, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7000

BIT

PDO Channel 2 (Index #x1601, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7010

BIT

PDO Channel 3 (Index #x1602, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7020

BIT

PDO Channel 4 (Index #x1603, Flags #x0011, SyncMan 0)

Name

Comment

BitLen

Index

Type

Output

#x7030

BIT

Term 22 (EK1110)

EtherCAT
Basic Settings

Name

Data

Name

Term 22 (EK1110)

ID

22

Box 23 (CU1128)

EtherCAT
Basic Settings

Name

Data

Name

Box 23 (CU1128)

ID

23

plc-lfe-optics

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-lfe-optics

ID

24

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ee6002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

12

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1801

BIT

None

1

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

64

#x10f4

ULINT

External time stamp

64

#x10f4

ULINT

None

32

ARRAY [0..3] OF BYTE

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

32

#x10f4

UDINT

External time stamp

32

#x10f4

UDINT

None

32

ARRAY [0..3] OF BYTE

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

16

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

MR1L0_Pitch_ENC

#x6000

ULINT

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-lfe-vacuum

EtherCAT (5 PDOs)
Basic Settings

Name

Data

Name

plc-lfe-vacuum

ID

26

SyncMan

001000012600010001000000800000040001001026010000

SyncMan

001400012200010002000000800000040001001422010000

SyncMan

0018dc002400010003000000000000000000001824000000

SyncMan

001ede002000010004000000000000000200001e20010000

Fmmu

0000000000000000001800020100000001000000000000000000000000000000

Fmmu

0000000000000000001e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

6

ARRAY [0..5] OF BIT

None

3

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

1

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

6

ARRAY [0..5] OF BIT

None

3

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

1

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

64

#x10f4

ULINT

External time stamp

64

#x10f4

ULINT

Control Value for DC Master Clock

32

#x10f4

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

6

ARRAY [0..5] OF BIT

None

3

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

1

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

32

#x10f4

UDINT

External time stamp

32

#x10f4

UDINT

Control Value for DC Master Clock

32

#x10f4

UDINT

PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

Term 28 (CU1128-B)

EtherCAT
Basic Settings

Name

Data

Name

Term 28 (CU1128-B)

ID

28

Term 29 (CU1128-C)

EtherCAT
Basic Settings

Name

Data

Name

Term 29 (CU1128-C)

ID

29

Term 30 (EL9011)

EtherCAT
Basic Settings

Name

Data

Name

Term 30 (EL9011)

ID

30

plc-lfe-gem

EtherCAT (5 PDOs)
Basic Settings

Name

Data

Name

plc-lfe-gem

ID

34

SyncMan

001000012600010001000000800000040001001026010000

SyncMan

001400012200010002000000800000040001001422010000

SyncMan

0018dc002400010003000000000000000000001824010000

SyncMan

001ede002000010004000000000000000200001e20010000

Fmmu

0000000000000000001800020100000001000000000000000000000000000000

Fmmu

0000000000000000001e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..5] OF BIT

None

ARRAY [0..2] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1800

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1800

BIT

Control value update toggle

Bit toggles when new DC control data available

#x10f4

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

Control Value for DC Master Clock

#x10f4

UDINT

PDO IO Inputs (Index #x1a00, Flags #x0021, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1600, Flags #x0021, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-txi-lfe-optics

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-txi-lfe-optics

ID

36

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ee6002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

MR1L1_Y_ENC

#x6000

ULINT

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-txi-lfe-motion

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-txi-lfe-motion

ID

40

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ede002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1801

BIT

None

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

ULINT

External time stamp

#x10f4

ULINT

None

UDINT

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

#x10f4

BIT2

None

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

#x10f4

BIT

Internal time stamp

#x10f4

UDINT

External time stamp

#x10f4

UDINT

None

UDINT

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

#x7000

ST_BeamParams_IO

plc-txi-lfe-vacuum

EtherCAT (6 PDOs)
Basic Settings

Name

Data

Name

plc-txi-lfe-vacuum

ID

41

BootStrapData

0010140200141402

SyncMan

0010000426000100010000008000da050004001026010000

SyncMan

0016000422000100020000008000da050004001622010000

SyncMan

001cdc006400010003000000000000000000001c64010000

SyncMan

008ee0002000010004000000000000000200008e20010000

Fmmu

0000000000000000001c00020100000001000000000000000000000000000000

Fmmu

0000000000000000008e00010100000002000000000000000000000000000000

Fmmu

00000000000000000d0800010100000003000000000000000000000000000000

CoeProfile

5001

PDO SYNC Inputs (Index #x1a01, Flags #x0010, SyncMan 3)

Name

Comment

BitLen

Index

Type

None

12

ARRAY [0..11] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1801

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1801

BIT

None

1

ARRAY [0..0] OF BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

PDO SYNC Inputs (Index #x1a02, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1802

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1802

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

64

#x10f4

ULINT

External time stamp

64

#x10f4

ULINT

None

32

ARRAY [0..3] OF BYTE

PDO SYNC Inputs (Index #x1a03, Flags #x0010, SyncMan )

Name

Comment

BitLen

Index

Type

Sync Mode

0: no Syncronisation 1: Secondary side is Sync Master 2: Primary side is Sync Master

2

#x10f4

BIT2

None

10

ARRAY [0..9] OF BIT

TxPDO toggle

Bit toggles when new data from other side received

1

#x1803

BIT

TxPDO state

0: Other side is in OP state >0: Error

1

#x1803

BIT

Timestamp update toggle

Bit toggles when new timestamp data available

1

#x10f4

BIT

External device not connected

0: External device connected 1: External device not connected

1

#x10f4

BIT

Internal time stamp

32

#x10f4

UDINT

External time stamp

32

#x10f4

UDINT

None

32

ARRAY [0..3] OF BYTE

PDO FOE Info (Index #x1a05, Flags #x0020, SyncMan )

Name

Comment

BitLen

Index

Type

Data Bytes Pending

16

#xf650

UINT

PDO IO Inputs (Index #x1a08, Flags #x0020, SyncMan 3)

Name

Comment

BitLen

Index

Type

RequestedBP

#x6000

ST_BeamParams_IO

FFO1

#x6000

BOOL

FFO2

#x6000

BOOL

PDO IO Outputs (Index #x1608, Flags #x0020, SyncMan 2)

Name

Comment

BitLen

Index

Type

CurrentBP

240

#x7000

ST_BeamParams_IO