pcdsdevices.attenuator.HE_SATT_ConstantThickness_Holder

class pcdsdevices.attenuator.HE_SATT_ConstantThickness_Holder(*args, **kwargs)
Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

holder_name

PytmcSignal

:Name

Name of filter.

normal

Inherited from HE_SATT_FilterHolder

enabled

PytmcSignal

:Enabled

Filter enabled for transmission requests.

normal

Inherited from HE_SATT_FilterHolder

curr_trans

PytmcSignal

:CurTrans

Current transmission through this holder.

normal

Inherited from HE_SATT_FilterHolder

curr_trans_3rd

PytmcSignal

:CurTrans3rd

Current third harmonic transmission through this holder.

normal

Inherited from HE_SATT_FilterHolder

curr_safe_power

PytmcSignal

:CurSafePower

Current safe power for this holder in watts.

normal

Inherited from HE_SATT_FilterHolder

out_position

PytmcSignal

:OutPos

Out position for holder in axis units.

normal

Inherited from HE_SATT_FilterHolder

active_filter

PytmcSignal

:ActiveFiltName

Name of active filter in this holder or None.

normal

Inherited from HE_SATT_FilterHolder

rtd1

TwinCATTempSensor

:RTD:01

First thermocouple.

normal

Inherited from HE_SATT_FilterHolder

rtd2

TwinCATTempSensor

:RTD:02

Second thermocouple.

normal

Inherited from HE_SATT_FilterHolder

filter1

HE_SATT_FilterConstantThickness

:Filter:01

normal

filter2

HE_SATT_FilterConstantThickness

:Filter:02

normal

filter3

HE_SATT_FilterConstantThickness

:Filter:03

normal

filter4

HE_SATT_FilterConstantThickness

:Filter:04

normal

filter5

HE_SATT_FilterConstantThickness

:Filter:05

normal

filter6

HE_SATT_FilterConstantThickness

:Filter:06

normal

filter7

HE_SATT_FilterConstantThickness

:Filter:07

normal

filter8

HE_SATT_FilterConstantThickness

:Filter:08

normal

filter9

HE_SATT_FilterConstantThickness

:Filter:09

normal

filter10

HE_SATT_FilterConstantThickness

:Filter:10

normal

filter11

HE_SATT_FilterConstantThickness

:Filter:11

normal

filter12

HE_SATT_FilterConstantThickness

:Filter:12

normal

Methods

configure(d: Dict[str, Any]) → Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() → OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

post_elog_status()

Post device status to the primary elog, if possible.

read() → OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() → OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

classmethod set_defaults(*, connection_timeout=10.0)

Set class-wide defaults for device communications

This may be called only before any instances of Device are made.

This setting applies to the class it is called on and all its subclasses. For example,

>>> Device.set_defaults(...)

will apply to any Device subclass.

Parameters:

connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC.

Raises:

RuntimeError – If called after EpicsSignalBase has been instantiated for the first time.

status() → str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() → StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
connection_timeout
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})