pcdsdevices.dccm.DCCMEnergyWithVernier
- class pcdsdevices.dccm.DCCMEnergyWithVernier(prefix: str, hutch: str | None = None, **kwargs)
DCCM energy motor that also requests a Vernier/ACR energy change.
The hutch component is an enum dropdown selecting the ACR destination.
DCCM energy is specified in keV; the ACR request is specified in eV. Both move statuses are combined. For the no-wait ACR variant, the ACR status may complete once the request is accepted, rather than when the physical beam-energy change has completed.
Changing the selection affects subsequent requests only. It does not redirect an in-progress request or change physical beam routing.
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
high_limit_travel
InternalSignalconfig
Inherited from
DCCMEnergylow_limit_travel
InternalSignalconfig
Inherited from
DCCMEnergysetpoint
:CmdkeVThe target energy setpoint signal in keV.
normal
Inherited from
DCCMEnergyreadback
EpicsSignalRO:EstEnergy_RBVThe current estimated energy readback signal in keV.
hinted
Inherited from
DCCMEnergyuser_readback
EpicsSignalRO:EstEnergy_RBVomitted
Inherited from
DCCMEnergyactuate
:CmdMoveEnergyCommand signal to initiate the energy move sequence.
omitted
Inherited from
DCCMEnergydone
EpicsSignalRO:Done_RBVPLC completion acknowledgement used by the move handshake.
normal
Inherited from
DCCMEnergystop_signal
EpicsSignal:CmdStopCommand signal to abort current energy adjustments.
omitted
Inherited from
DCCMEnergyreset
:CmdResetCommand signal to reset faults or clear movement cycles.
omitted
Inherited from
DCCMEnergyangle_offset
:AngleOffsetAngular offset adjustment value for tuning crystal geometry.
config
Inherited from
DCCMEnergyctrl_velo_bias_gain
:CtrlVeloBiasGainVelocity bias gain modifier for the underlying controller.
config
Inherited from
DCCMEnergylat_const_scaler
:LatConstScalerLattice constant scaling modifier.
config
Inherited from
DCCMEnergycrystal_type
:TypeThe identifier string or type index for the crystal material/cut.
config
Inherited from
DCCMEnergycoeff
EpicsSignalRO:Coeff_RBVCalculated tracking coefficient.
normal
Inherited from
DCCMEnergyest_pos_delta
EpicsSignalRO:EstPosDelta_RBVDifference between estimated position and goal.
hinted
Inherited from
DCCMEnergyest_energy_delta
EpicsSignalRO:EstEnergyDelta_RBVDifference between estimated energy and goal.
hinted
Inherited from
DCCMEnergyest_energy
EpicsSignalRO:EstEnergy_RBVAlias of the estimated energy readback.
omitted
Inherited from
DCCMEnergystate
EpicsSignalRO:State_RBVCurrent operational state enum from EPICS.
normal
Inherited from
DCCMEnergyerror
EpicsSignalRO:Error_RBVBoolean indicating an error status.
normal
Inherited from
DCCMEnergywarning
EpicsSignalRO:Warning_RBVBoolean indicating a warning status.
normal
Inherited from
DCCMEnergyerror_msg
EpicsSignalRO:ErrorMsg_RBVDiagnostic string explaining the current error state.
normal
Inherited from
DCCMEnergywarning_msg
EpicsSignalRO:WarningMsg_RBVDiagnostic string explaining the current warning state.
normal
Inherited from
DCCMEnergyaxis_coupling_enable (FCpt)
{self._base_prefix}:CTC:CoupledCommand to enable/disable crystal-axis coupling.
omitted
Inherited from
DCCMEnergyhutch
Selected beam destination / ACR request hutch.
config
acr_requests
ACR request devices for the available hutches.
normal
Methods
- camonitor()
Shows a live-updating motor position in the terminal.
This will be the value that is returned by the
positionattribute.This method ends cleanly at a ctrl+c or after a call to
end_monitor_thread(), which may be useful when this is called in a background thread.
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- couple_axis(*args, **kwargs)
- decouple_axis(*args, **kwargs)
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- end_monitor_thread()
Stop a
camonitor()orwm_update()that is running in another thread.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- move(position, wait=True, timeout=None, moved_cb=None)
Request an energy move and return its complete handshake status.
With wait=False, return after issuing the command writes. The returned status completes only after Done_RBV transitions high and then low following reset acknowledgement.
- Parameters:
- Returns:
ophyd.status.MoveStatus – Status representing the entire PLC handshake.
- mv(position, timeout=None, wait=False, log=True)
Absolute move to a position.
- Parameters:
position – Desired end position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
wait (bool, optional) – If
True, wait for motion completion before returning. Defaults toFalse.log (bool, optional) – If
True, logs the move at INFO level.
- mv_ginput(timeout=None)
Moves to a location the user clicks on.
If there are existing plots, this will be the position on the most recently active plot. If there are no existing plots, an empty plot will be created with the motor’s limits as the range.
- mvr(delta, timeout=None, wait=False, log=True)
Relative move from this position.
- Parameters:
delta (float) – Desired change in position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
wait (bool, optional) – If
True, wait for motion completion before returning. Defaults toFalse.log (bool, optional) – If
True, logs the move at INFO level.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- set(new_position: Any, *, timeout: float = None, moved_cb: Callable = None, wait: bool = False) StatusBase
Set a value and return a Status object
- Parameters:
new_position (object) – The input here is whatever the device requires (this should be over-ridden by the implementation. For example a motor would take a float, a shutter the strings {‘Open’, ‘Close’}, and a goineometer (h, k, l) tuples
timeout (float, optional) – Maximum time to wait for the motion. If None, the default timeout for this positioner is used.
moved_cb (callable, optional) –
Deprecated
Call this callback when movement has finished. This callback must accept one keyword argument: ‘obj’ which will be set to this positioner instance.
wait (bool, optional) –
Deprecated
If the method should block until the Status object reports it is done.
Defaults to False
- Returns:
status (StatusBase) – Status object to indicate when the motion / set is done.
- classmethod set_defaults(*, connection_timeout=10.0)
Set class-wide defaults for device communications
This may be called only before any instances of Device are made.
This setting applies to the class it is called on and all its subclasses. For example,
>>> Device.set_defaults(...)
will apply to any Device subclass.
- Parameters:
connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC.
- Raises:
RuntimeError – If called after
EpicsSignalBasehas been instantiated for the first time.
- set_position(position)
Alias for set_current_position.
Will fail if the motor does not have set_current_position.
- stop(*, success=False)
Issue PLC stop and finish any active software move status.
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
- tweak(scale=0.1)
Control this motor using the arrow keys.
Use left arrow to step negative and right arrow to step positive. Use up arrow to increase step size and down arrow to decrease step size. Press q or ctrl+c to quit.
- Parameters:
scale (float) – starting step size, default = 0.1
- umv(position, timeout=None, log=True, newline=True)
Move to a position, wait, and update with a progress bar.
- Parameters:
position (float) – Desired end position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
log (bool, optional) – If True, logs the move at INFO level.
newline (bool, optional) – If True, inserts a newline after the updates.
- umvr(delta, timeout=None, log=True, newline=True)
Relative move from this position, wait, and update with a progress bar.
- Parameters:
delta (float) – Desired change in position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
log (bool, optional) – If True, logs the move at INFO level.
newline (bool, optional) – If True, inserts a newline after the updates.
- wait(timeout=None)
- wm()
Get the mover’s current positon (where motor).
- wm_update()
Shows a live-updating motor position in the terminal.
This will be the value that is returned by the
positionattribute.This method ends cleanly at a ctrl+c or after a call to
end_monitor_thread(), which may be useful when this is called in a background thread.
Attributes
- ACTUATE_VALUE = 1
- DEFAULT_MOVE_TIMEOUT = 10.0
- DONE_HIGH_VALUE = 1
- DONE_LOW_VALUE = 0
- RESET_VALUE = 1
- STOP_VALUE = 1
- acr_energy
ACR request device for the currently selected hutch.
- actuate_value = 1
- configuration_attrs
- connected
- connection_timeout
- done_value = 1
- egu
The engineering units (EGU) for a position
- high_limit
- hints
- hutch_name
Currently selected destination.
- kind
- limits
- low_limit
- moving
Whether this Python device currently has an active move.
Done_RBV uses zero for both idle and moving states, so this property tracks only moves initiated through this instance.
- position
The current position of the motor in its engineering units
- Returns:
position (any)
- put_complete
- settle_time
Amount of time to wait after moves to report status completion
- stop_value = 1
- subscriptions: ClassVar[FrozenSet[str]] = frozenset({'_req_done', 'acq_done', 'done_moving', 'readback', 'start_moving'})
- timeout
Amount of time to wait before to considering a motion as failed