pcdsdevices.fms.LCP1
- class pcdsdevices.fms.LCP1(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, child_name_separator='_', connection_timeout=<object object>, **kwargs)
- For LCPs with CMC-III PU, with Door Module off - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - temperature_f - EpicsSignalRO- :Temperature_CALC- hinted - power_v_supply_v - EpicsSignalRO- :24Vsupply_CALC- hinted - air_fan_1_rpm_percent - EpicsSignalRO- :AirFan1Rpm_CALC- hinted - air_fan_2_rpm_percent - EpicsSignalRO- :AirFan2Rpm_CALC- hinted - air_fan_3_rpm_percent - EpicsSignalRO- :AirFan3Rpm_CALC- hinted - air_fan_4_rpm_percent - EpicsSignalRO- :AirFan4Rpm_CALC- hinted - air_fan_5_rpm_percent - EpicsSignalRO- :AirFan5Rpm_CALC- hinted - air_fan_6_rpm_percent - EpicsSignalRO- :AirFan6Rpm_CALC- hinted - water_temp_in_f - EpicsSignalRO- :WaterTempIn_CALC- hinted - water_temp_out_f - EpicsSignalRO- :WaterTempOut_CALC- hinted - water_flow_rate_gpm - EpicsSignalRO- :WaterFlowRate_CALC- hinted - air_temp_in_top_f - EpicsSignalRO- :AirTempInTop_CALC- hinted - air_temp_in_mid_f - EpicsSignalRO- :AirTempInMid_CALC- hinted - air_temp_in_bot_f - EpicsSignalRO- :AirTempInBot_CALC- hinted - air_temp_out_top_f - EpicsSignalRO- :AirTempOutTop_CALC- hinted - air_temp_out_mid_f - EpicsSignalRO- :AirTempOutMid_CALC- hinted - air_temp_out_bot_f - EpicsSignalRO- :AirTempOutBot_CALC- hinted - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns:
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns:
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - read() OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - classmethod set_defaults(*, connection_timeout=10.0)
- Set class-wide defaults for device communications - This may be called only before any instances of Device are made. - This setting applies to the class it is called on and all its subclasses. For example, - >>> Device.set_defaults(...) - will apply to any Device subclass. - Parameters:
- connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC. 
- Raises:
- RuntimeError – If called after - EpicsSignalBasehas been instantiated for the first time.
 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns:
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - connection_timeout
 - hints
 - kind