pcdsdevices.gauge.GaugeSerial
- class pcdsdevices.gauge.GaugeSerial(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, child_name_separator='_', connection_timeout=<object object>, **kwargs)
- Base class for Vacuum Gauges controlled via serial. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - gastype - EpicsSignal- :GASTYPE- omitted - gastypedes - EpicsSignal- :GASTYPEDES- omitted - hystsprbck_1 - EpicsSignalRO- :HYSTSPRBCK_1_RBV- omitted - hystsprbck_2 - EpicsSignalRO- :HYSTSPRBCK_2_RBV- omitted - p - EpicsSignal- :P- omitted - padel - EpicsSignal- :PADEL- omitted - plog - EpicsSignal- :PLOG- omitted - pmon - EpicsSignal- :PMON- omitted - pmonraw - EpicsSignal- :PMONRAW- omitted - pstat_1 - EpicsSignal- :PSTAT_1- omitted - pstat_2 - EpicsSignal- :PSTAT_2- omitted - pstat_calc - EpicsSignal- :PSTAT_CALC- omitted - pstat_sum - EpicsSignal- :PSTAT_SUM- omitted - pstatdirdes_1 - EpicsSignal- :PSTATDIRDES_1- omitted - pstatdirdes_2 - EpicsSignal- :PSTATDIRDES_2- omitted - pstatenable_1 - EpicsSignal- :PSTATENABLE_1- omitted - pstatenable_2 - EpicsSignal- :PSTATENABLE_2- omitted - pstatenades_1 - EpicsSignal- :PSTATENADES_1- omitted - pstatenades_2 - EpicsSignal- :PSTATENADES_2- omitted - pstatspdes_1 - EpicsSignal- :PSTATSPDES_1- omitted - pstatspdes_2 - EpicsSignal- :PSTATSPDES_2- omitted - pstatspdir_1 - EpicsSignal- :PSTATSPDIR_1- omitted - pstatspdir_2 - EpicsSignal- :PSTATSPDIR_2- omitted - pstatsprbck_1 - EpicsSignalRO- :PSTATSPRBCK_1_RBV- omitted - pstatsprbck_2 - EpicsSignalRO- :PSTATSPRBCK_2_RBV- omitted - state - EpicsSignal- :STATE- omitted - statedes - EpicsSignal- :STATEDES- omitted - staterbck - EpicsSignalRO- :STATERBCK_RBV- omitted - status_rs - EpicsSignal- :STATUS_RS- omitted - status_rs_calc1 - EpicsSignal- :STATUS_RS_CALC1- omitted - status_rs_calc2 - EpicsSignal- :STATUS_RS_CALC2- omitted - status_rscalc - EpicsSignal- :STATUS_RSCALC- omitted - status_rscalc2 - EpicsSignal- :STATUS_RSCALC2- omitted - status_rsmon - EpicsSignal- :STATUS_RSMON- omitted - status_rsout - EpicsSignal- :STATUS_RSOUT- omitted - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns:
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns:
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - read() OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - classmethod set_defaults(*, connection_timeout=10.0)
- Set class-wide defaults for device communications - This may be called only before any instances of Device are made. - This setting applies to the class it is called on and all its subclasses. For example, - >>> Device.set_defaults(...) - will apply to any Device subclass. - Parameters:
- connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC. 
- Raises:
- RuntimeError – If called after - EpicsSignalBasehas been instantiated for the first time.
 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns:
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - connection_timeout
 - hints
 - kind