pcdsdevices.pdu.TripplitePDU24
- class pcdsdevices.pdu.TripplitePDU24(prefix, name=None, **kwargs)
- 24-channel Tripplite PDU with static channel definitions for Typhos - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - tower_name - EpicsSignal- :setDeviceName- hinted - Inherited from - TripplitePDU- location - EpicsSignal- :setDeviceLocation- hinted - Inherited from - TripplitePDU- status - EpicsSignalRO- :getDeviceStatus- hinted - Inherited from - TripplitePDU- num_inputs - EpicsSignalRO- :getPduIdentNumInputs- hinted - Inherited from - TripplitePDU- num_outputs - EpicsSignalRO- :getPduIdentNumOutputs- hinted - Inherited from - TripplitePDU- num_outlets - EpicsSignalRO- :getPduIdentNumOutlets- hinted - Inherited from - TripplitePDU- num_groups - EpicsSignalRO- :getPduIdentNumOutletGroups- hinted - Inherited from - TripplitePDU- num_phases - EpicsSignalRO- :getPduIdentNumPhases- hinted - Inherited from - TripplitePDU- num_circuits - EpicsSignalRO- :getPduIdentNumCircuits- hinted - Inherited from - TripplitePDU- num_breakers - EpicsSignalRO- :getPduIdentNumBreakers- hinted - Inherited from - TripplitePDU- num_heatsinks - EpicsSignalRO- :getPduIdentNumHeatsinks- hinted - Inherited from - TripplitePDU- input_f - EpicsSignalRO- :getPduInputPhaseFrequency- hinted - Inherited from - TripplitePDU- input_v - EpicsSignalRO- :getPduInputPhaseVoltage- hinted - Inherited from - TripplitePDU- input_v_min - EpicsSignalRO- :getPduInputPhaseVoltageMin- hinted - Inherited from - TripplitePDU- input_v_max - EpicsSignalRO- :getPduInputPhaseVoltageMax- hinted - Inherited from - TripplitePDU- output_f - EpicsSignalRO- :getPduOutputFrequency- hinted - Inherited from - TripplitePDU- output_v - EpicsSignalRO- :getPduOutputVoltage- hinted - Inherited from - TripplitePDU- output_p - EpicsSignalRO- :getPduOutputActivePower- hinted - Inherited from - TripplitePDU- output_c - EpicsSignalRO- :getPduOutputCurrent- hinted - Inherited from - TripplitePDU- output_c_min - EpicsSignalRO- :getPduOutputCurrentMin- hinted - Inherited from - TripplitePDU- output_c_max - EpicsSignalRO- :getPduOutputCurrentMax- hinted - Inherited from - TripplitePDU- channels_on - EpicsSignal- :setPduControlPduOn- hinted - Inherited from - TripplitePDU- channels_off - EpicsSignal- :setPduControlPduOff- hinted - Inherited from - TripplitePDU- channels_reboot - EpicsSignal- :setPduControlPduReboot- hinted - Inherited from - TripplitePDU- channel1 - normal - channel2 - normal - channel3 - normal - channel4 - normal - channel5 - normal - channel6 - normal - channel7 - normal - channel8 - normal - channel9 - normal - channel10 - normal - channel11 - normal - channel12 - normal - channel13 - normal - channel14 - normal - channel15 - normal - channel16 - normal - channel17 - normal - channel18 - normal - channel19 - normal - channel20 - normal - channel21 - normal - channel22 - normal - channel23 - normal - channel24 - normal - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns:
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns:
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - read() OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - classmethod set_defaults(*, connection_timeout=10.0)
- Set class-wide defaults for device communications - This may be called only before any instances of Device are made. - This setting applies to the class it is called on and all its subclasses. For example, - >>> Device.set_defaults(...) - will apply to any Device subclass. - Parameters:
- connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC. 
- Raises:
- RuntimeError – If called after - EpicsSignalBasehas been instantiated for the first time.
 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns:
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - connection_timeout
 - hints
 - kind