pcdsdevices.pneumatic.BeckhoffPneumaticFDQ
- class pcdsdevices.pneumatic.BeckhoffPneumaticFDQ(*args, **kwargs)
- Beckhoff Pneumatics with a flow meter for cooling readback. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - lightpath_summary - omitted - Inherited from - BeckhoffPneumatic- limit_switch_in - :PLC:bInLimitSwitch- normal - Inherited from - BeckhoffPneumatic- limit_switch_out - :PLC:bOutLimitSwitch- normal - Inherited from - BeckhoffPneumatic- retract_status - :bRetractDigitalOutput- normal - Inherited from - BeckhoffPneumatic- insert_status - :bInsertDigitalOutput- normal - Inherited from - BeckhoffPneumatic- interlock_ok - :bInterlockOK- normal - Inherited from - BeckhoffPneumatic- insert_ok - :bInsertEnable- normal - Inherited from - BeckhoffPneumatic- retract_ok - :bRetractEnable- normal - Inherited from - BeckhoffPneumatic- insert_signal - :CMD:IN- normal - Inherited from - BeckhoffPneumatic- retract_signal - :CMD:OUT- normal - Inherited from - BeckhoffPneumatic- busy - :bBusy- normal - Inherited from - BeckhoffPneumatic- done - :bDone- normal - Inherited from - BeckhoffPneumatic- reset - :bReset- normal - Inherited from - BeckhoffPneumatic- error - :PLC:bError- normal - Inherited from - BeckhoffPneumatic- error_id - :PLC:nErrorId- normal - Inherited from - BeckhoffPneumatic- error_message - :PLC:sErrorMessage- normal - Inherited from - BeckhoffPneumatic- position_state - :nPositionState- hinted - Inherited from - BeckhoffPneumatic- flow_meter - Device that measures PCW Flow Rate. - normal - Methods - calc_lightpath_state(limit_switch_in=None, limit_switch_out=None)
- Create and return a LightpathState object containing information needed for lightpath, given a set of signal values - kwargs should be the same as the signal names provided in - lightpath_cpts- Device logic goes here. - Returns:
- LightpathState – a dataclass containing the Lightpath state 
 
 - callback(*, old_value, value, **kwargs)
 - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns:
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns:
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - get_lightpath_state(use_cache: bool = True) LightpathState
- Return the current LightpathState - Returns:
- LightpathState – a dataclass containing the Lightpath state 
 
 - insert(wait: bool = False, timeout: float = 10.0) Status
- Method for inserting Beckhoff Pneumatic Actuator 
 - post_elog_status()
- Post device status to the primary elog, if possible. 
 - read() OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - remove(wait: bool = False, timeout: float = 10.0) Status
- Method for removing Beckhoff Pneumatic Actuator 
 - screen()
- Open a screen for controlling the device. - Default behavior is the typhos screen, but this method can be overridden for more specialized screens. 
 - classmethod set_defaults(*, connection_timeout=10.0)
- Set class-wide defaults for device communications - This may be called only before any instances of Device are made. - This setting applies to the class it is called on and all its subclasses. For example, - >>> Device.set_defaults(...) - will apply to any Device subclass. - Parameters:
- connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC. 
- Raises:
- RuntimeError – If called after - EpicsSignalBasehas been instantiated for the first time.
 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns:
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - connection_timeout
 - hints
 - kind
 - lightpath_cpts = ['limit_switch_in', 'limit_switch_out']
 - md