pcdsdevices.signal.EpicsSignalROEditMD
- class pcdsdevices.signal.EpicsSignalROEditMD(read_pv, *, string=False, name=None, **kwargs)
- EpicsSignal variant which allows for user correction of various metadata. - Parameters:
- enum_strings (list of str, optional) – List of enum strings to replace the EPICS originals. May not be used in conjunction with the dynamic - enum_attrs.
- enum_attrs (list of str, optional) – List of signal attribute names, relative to the parent device. That is to say a given attribute is assumed to be a sibling of this signal instance. Attribute names may be - Nonein the case where the original enum string should be passed through.
 
 - See also - None,- A,- one,- Keyword- Parameters:
- read_pv (str) – The PV to read from 
- limits (bool, optional) – Check limits prior to writing value 
- auto_monitor (bool, optional) – Use automonitor with epics.PV 
- name (str, optional) – Name of signal. If not given defaults to read_pv 
- timeout (float or None, optional) – - The timeout for serving a read request on a connected channel. This is only applied if the PV is connected within connection_timeout (below). - The default value DEFAULT_TIMEOUT means, “Fall back to class-wide default.” See EpicsSignalBase.set_defaults to configure class defaults. - Explicitly passing None means, “Wait forever.” 
- write_timeout (float or None, optional) – - The timeout for a reply when put completion is used. This is only applied if the PV is connected within connection_timeout (below). - This is very different than the connection and read timeouts above. It relates to how long an action takes to complete, such motor motion or data acquisition. Any default value we choose here is likely to cause problems—either by being too short and giving up too early on a lengthy action or being too long and delaying the report of a failure. A finite value can be injected here or, perhaps more usefully, via - setat the Device level, where a context-appropriate value can be chosen.
- connection_timeout (float or None, optional) – - Timeout for connection. This includes the time to search and establish a channel. - The default value DEFAULT_CONNECTION_TIMEOUT means, “Fall back to class-wide default.” See EpicsSignalBase.set_defaults to configure class defaults. - Explicitly passing None means, “Wait forever.” 
 
 - Methods - describe()
- Return the signal description as a dictionary. - Units, limits, precision, and enum strings may be overridden. - Returns:
- dict – Dictionary of name and formatted description string 
 
 - get(*, count=None, as_string=None, timeout=<object object>, connection_timeout=<object object>, form='time', use_monitor=None, **kwargs)
- Get the readback value through an explicit call to EPICS. - Parameters:
- count (int, optional) – Explicitly limit count for array data 
- as_string (bool, optional) – Get a string representation of the value, defaults to as_string from this signal, optional 
- as_numpy (bool) – Use numpy array as the return type for array data. 
- timeout (float, optional) – maximum time to wait for value to be received. (default = 0.5 + log10(count) seconds) 
- use_monitor (bool, optional) – to use value from latest monitor callback or to make an explicit CA call for the value. (default: True) 
- connection_timeout (float, optional) – If not already connected, allow up to - connection_timeoutseconds for the connection to complete.
- form ({'time', 'ctrl'}) – PV form to request 
 
 
 - read()
- Put the status of the signal into a simple dictionary format for data acquisition - Returns:
- dict 
 
 - read_configuration()
- Dictionary mapping names to value dicts with keys: value, timestamp 
 - set(*args, **kwargs)
- Disabled for a read-only signal 
 - classmethod set_default_timeout(**kwargs)
 - classmethod set_defaults(*, timeout=2.0, connection_timeout=1.0, write_timeout=None, auto_monitor=False)
- Set class-wide defaults for EPICS CA communications - This may be called only before any instances of EpicsSignalBase are made. - This setting applies to the class it is called on and all its subclasses. For example, - >>> EpicsSignalBase.set_defaults(...) - will apply to - EpicsSignalROand- EpicsSignal, which are both subclasses of- EpicsSignalBase.- but - >>> EpicsSignal.set_defaults(...) - will not apply to - EpicsSignalRO.- Parameters:
- auto_monitor (bool, optional) – If - True, update cached value from EPICS CA monitor callbacks. If- False, request new value from EPICS each time get() is called.
- connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC. 
- timeout (float, optional) – Total time budget (seconds) for reading, not including connection time. 
- write_timeout (float, optional) – Time (seconds) allocated for writing, not including connection time. The write_timeout is very different than the connection and read timeouts above. It relates to how long an action takes to complete. Any default value we choose here is likely to cause problems—either by being too short and giving up too early on a lengthy action or being too long and delaying the report of a failure. The default, None, waits forever. 
 
- Raises:
- RuntimeError – If called after - EpicsSignalBasehas been instantiated for the first time.
 
 - trigger()
- Call that is used by bluesky prior to read() 
 - Attributes - SUB_META = 'meta'
 - alarm_severity
- PV alarm severity 
 - alarm_status
- PV status 
 - as_string
- Attempt to cast the EPICS PV value to a string by default 
 - connected
- Is the signal connected and ready to use? 
 - connection_timeout
 - enum_attrs
- Enum attribute names - the source of each enum string. 
 - enum_strs
- List of enum strings. - For an EpicsSignalEditMD, this could be one of: - The original enum strings from the PV 
- The strings found from the respective signals referenced by
- enum_attrs.
 
- The user-provided strings in - enum_strs.
 
 - high_limit
- The high, inclusive control limit for the Signal 
 - hints
- Field hints for plotting 
 - kind
 - limits
- The PV limits as reported by EPICS (or EpicsSignalEditMD). 
 - low_limit
- The low, inclusive control limit for the Signal 
 - metadata
 - metadata_keys
- Metadata keys that will be passed along on value subscriptions 
 - precision
- The PV precision as reported by EPICS (or EpicsSignalEditMD). 
 - pvname
- The readback PV name 
 - read_access
- Can the signal be read? 
 - source_name
 - timeout
 - timestamp
- Timestamp of readback PV, according to EPICS 
 - tolerance
- The absolute tolerance associated with the value. 
 - value
- The signal’s value 
 - write_access
- Can the signal be written to? 
 - write_timeout