pcdsdevices.pump.Kashiyama_G_Serial

class pcdsdevices.pump.Kashiyama_G_Serial(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, child_name_separator='_', connection_timeout=<object object>, **kwargs)

Class for the Kashiyama Neo Dry G-Series IOC

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

run_cmd

EpicsSignal

:CMD

normal

run

EpicsSignalRO

:RUN_RBV

normal

mode_cmd

EpicsSignal

:OPMODE

normal

mode_cmd_rbv

EpicsSignalRO

:OPMODE_RBV

normal

freq

EpicsSignalRO

:FREQ_HZ

normal

freq_cpm

EpicsSignal

:FREQSET

normal

freq_cpm_rbv

EpicsSignalRO

:FREQSET_RBV

normal

lspd_freq_cpm_rbv

EpicsSignalRO

:LOWFREQSET_RBV

normal

current

EpicsSignalRO

:CURR_RBV

normal

voltage

EpicsSignalRO

:VOLT_RBV

normal

power

EpicsSignalRO

:PWR_RBV

normal

motor_temp

EpicsSignalRO

:MTRTEMP_RBV

normal

driver_temp

EpicsSignalRO

:DRVTEMP_RBV

omitted

ipm_temp

EpicsSignalRO

:IPMTEMP_RBV

omitted

warn

EpicsSignalRO

:WARN_RBV

normal

alarm

EpicsSignalRO

:ALM_RBV

normal

error_count

EpicsSignalRO

:ERRCNT_RBV

omitted

error_reset

EpicsSignal

:ERRRST

normal

valve_status

EpicsSignalRO

:VALVE_RBV

normal

fan_status

EpicsSignalRO

:FAN_RBV

normal

overhaul_one

EpicsSignalRO

:OVHL1_RBV

omitted

overaul_two

EpicsSignalRO

:OVHL2_RBV

omitted

run_time

EpicsSignalRO

:RTIME_RBV

omitted

run_time_post_overhaul

EpicsSignalRO

:RTIME_OH_RBV

omitted

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

classmethod set_defaults(*, connection_timeout=10.0)

Set class-wide defaults for device communications

This may be called only before any instances of Device are made.

This setting applies to the class it is called on and all its subclasses. For example,

>>> Device.set_defaults(...)

will apply to any Device subclass.

Parameters:

connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC.

Raises:

RuntimeError – If called after EpicsSignalBase has been instantiated for the first time.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
connection_timeout
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})