pcdsdevices.analog_signals.Mesh
- class pcdsdevices.analog_signals.Mesh(prefix, sp_ch, rb_ch, scale=1000.0, name=None)
- Class for Mesh HV Supply that is connected to Acromag inputs and outputs. - The standard Device - nameparameter is ignored here and replaced with- "mesh_raw".- Parameters
- prefix (str) – Prefix of Acromag to be used. 
- sp_ch (int) – Setpoint Acromag channel to which high voltage supply setpoint is connected. Range is 0 to 15. 
- rb_ch (int) – Read back Acromag channel to which high voltage readback is connected. Range is 0 to 15. 
- scale (float, optional) – Gain for high voltage supply to be controlled by the Acromag. 
 
 - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - write_sig (FCpt) - EpicsSignal- {self.prefix}:ao1:{self.sp_ch}- normal - read_sig (FCpt) - EpicsSignalRO- {self.prefix}:ai1:{self.rb_ch}- normal - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - get_mesh_voltage()
- Get the current mesh voltage setpoint, i.e. the setpoint that the HV supply attempts to output. 
 - get_raw_mesh_voltage()
- Get the current acromag voltage that outputs to the HV supply, i.e. the voltage seen by the HV supply. 
 - read() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - set_mesh_voltage(hv_sp, wait=True)
- Set mesh voltage to an absolute value in V. - Parameters
- hv_sp (float) – Desired power supply setpoint in V. Acromag will output necessary voltage such that the HV supply achieves the value passed to hv_sp. 
- wait (bool, optional) – Indicates whether or not the program should pause when writing to a PV. 
- do_print (bool, optional) – Indicates whether or not the program should print it’s setpoint and readback values. 
 
 
 - set_rel_mesh_voltage(delta_hv_sp, wait=True)
- Increase/decrease the power supply setpoint by a specified amount. - Parameters
- delta_hv_sp (float) – Amount to increase/decrease the power supply setpoint (in V) from its current value. Use positive to increase and negative to decrease. 
 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() ophyd.status.StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - tweak_mesh_voltage(delta_hv_sp, test_flag=False)
- Increase/decrease power supply setpoint using the arrow keys. - Use ‘q’ or ^C to exit tweak mode. - Parameters
- delta_hv_sp (float) – Amount to change voltage from its current value at each step, measured in volts. After calling with specified step size, use arrow keys to keep changing. Use absolute value of increment size. 
- test_flag (bool, optional) – Flag used in testing functions to only run - while Trueloop once - i.e. single tweak mode.
 
 
 - Attributes - configuration_attrs
 - connected
 - hints
 - kind