pcdsdevices.valve.VGC_2S
- class pcdsdevices.valve.VGC_2S(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)
- Class for Controlled Gate Valves with 2 setpoints. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - open_command - :OPN_SW- Epics command to Open valve - normal - Inherited from - VGC- interlock_ok - EpicsSignalRO- :OPN_OK_RBV- Valve is OK to Open interlock - normal - Inherited from - VGC- open_do - EpicsSignalRO- :OPN_DO_RBV- PLC Output to Open valve, 1 means 24V on command cable - normal - Inherited from - VGC- error_reset - :ALM_RST- Reset Error state to valid by toggling this - normal - Inherited from - VGC- override_status - EpicsSignalRO- :OVRD_ON_RBV- Epics Readback on Override mode - omitted - Inherited from - VGC- override_force_open - :FORCE_OPN- Epics Command to force open the valve inoverride mode - omitted - Inherited from - VGC- state - EpicsSignalRO- :STATE_RBV- Valve state - normal - Inherited from - VGC- open_limit - EpicsSignalRO- :OPN_DI_RBV- Open limit switch digital input - hinted - Inherited from - VGC- closed_limit - EpicsSignalRO- :CLS_DI_RBV- Closed limit switch digital input - hinted - Inherited from - VGC- diff_press_ok - EpicsSignalRO- :DP_OK_RBV- Differential pressure interlock ok - normal - Inherited from - VGC- ext_ilk_ok - EpicsSignalRO- :EXT_ILK_OK_RBV- External interlock ok - normal - Inherited from - VGC- at_vac_setpoint - :AT_VAC_SP- AT VAC Set point value - config - Inherited from - VGC- setpoint_hysterisis - :AT_VAC_HYS- AT VAC Hysterisis - config - Inherited from - VGC- at_vac - EpicsSignalRO- :AT_VAC_RBV- at vacuum sp is reached - normal - Inherited from - VGC- error - EpicsSignalRO- :ERROR_RBV- Error Present - normal - Inherited from - VGC- mps_state - EpicsSignalRO- :MPS_FAULT_OK_RBV- individual valve MPS state for debugging - omitted - Inherited from - VGC- interlock_device_upstream - EpicsSignalRO- :ILK_DEVICE_US_RBV- Upstream vacuum device used forinterlocking this valve - config - Inherited from - VGC- interlock_device_downstream - EpicsSignalRO- :ILK_DEVICE_DS_RBV- Downstream vacuum device used forinterlocking this valve - config - Inherited from - VGC- at_vac_setpoint_ds - :AT_VAC_SP_DS- AT VAC Set point value for the downstream gauge - config - setpoint_hysterisis_ds - :AT_VAC_HYS_DS- AT VAC Hysterisis for the downstream setpoint - config - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - read() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() ophyd.status.StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - hints
 - kind
 - lightpath_cpts = ['open_limit', 'closed_limit']
 - transmission