pcdsdevices.attenuator.AttenuatorCalculatorBase
- class pcdsdevices.attenuator.AttenuatorCalculatorBase(prefix, *, name, **kwargs)
Base class for new-style caproto IOC attenuator calculator devices.
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
calc_mode
EpicsSignal:SYS:CalcModeFloor or Ceiling calculation
config
energy_source
EpicsSignal:SYS:EnergySourceUse beamline photon energy or custom energy?
config
energy_custom
EpicsSignal:SYS:CustomPhotonEnergyCustom energy to use for calculations [eV]
config
energy_actual
EpicsSignalRO:SYS:ActualPhotonEnergy_RBVThe reported beamline photon energy [eV]
normal
actual_transmission
EpicsSignalRO:SYS:ActualTransmission_RBVActual normalized transmission value
normal
actual_transmission_3omega
EpicsSignalRO:SYS:Actual3OmegaTransmission_RBVActual 3 omega normalized transmission value
normal
desired_transmission
EpicsSignal:SYS:DesiredTransmissionDesired normalized transmission value
normal
last_energy
EpicsSignalRO:SYS:LastPhotonEnergy_RBVThe photon energy used for the previous calculation; i.e., the one that goes along with
best_config.config
best_config
EpicsSignalRO:SYS:BestConfiguration_RBVThe best configuration of filters for the desired transmission
normal
best_config_bitmask
EpicsSignalRO:SYS:BestConfigurationBitmask_RBVThe best configuration of filters for the desired transmission.
normal
best_config_error
EpicsSignalRO:SYS:BestConfigError_RBVDesired to calculated transmission error
normal
active_config
EpicsSignalRO:SYS:ActiveConfiguration_RBVWhere the filters are now
omitted
active_config_bitmask
EpicsSignalRO:SYS:ActiveConfigurationBitmask_RBVWhere the filters are now (as an integer)
normal
filters_moving
EpicsSignalRO:SYS:FiltersMoving_RBVFilter-by-filter motion status (1 if moving)
normal
filters_moving_bitmask
EpicsSignalRO:SYS:FiltersMovingBitmask_RBVFilter-by-filter motion status as a bitmask
normal
run_calculation
EpicsSignal:SYS:RunStart the calculation
config
apply_config
EpicsSignal:SYS:ApplyConfigurationApply the best configuration (i.e., move the filters)
config
moving
EpicsSignalRO:SYS:Moving_RBVAre filters being moved in/out?
config
Methods
- calculate(transmission, *, energy=None, use_floor=True)
Calculate a blade configuration given a desired transmission value.
If
energyis not specified, this method defaults to using the current L-line photon energy, as reported by the Photon Machine Protection System:PMPS:LFE:PE:UND:CurrentPhotonEnergy_RBV.
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- get_active_config(**kwargs)
Get the active filter configuration.
- get_best_config(**kwargs)
Get the calculated (best) filter configuration.
- get_moving_status(**kwargs)
Get the filter motion status.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind