pcdsdevices.lasers.btps.BtpsVGC
- class pcdsdevices.lasers.btps.BtpsVGC(*args, input_branches=[], output_branches=[], **kwargs)
VGC subclass with ‘valve_position’ component added.
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
lightpath_summary
omitted
Inherited from
VGCvalve_position
EpicsSignalRO:POS_STATE_RBVEx: OPEN, CLOSED, MOVING, INVALID, OPEN_F
hinted
Inherited from
VGCopen_command
:OPN_SWEpics command to Open valve
normal
Inherited from
VGCinterlock_ok
EpicsSignalRO:OPN_OK_RBVValve is OK to Open interlock
normal
Inherited from
VGCopen_do
EpicsSignalRO:OPN_DO_RBVPLC Output to Open valve, 1 means 24V on command cable
normal
Inherited from
VGCerror_reset
:ALM_RSTReset Error state to valid by toggling this
normal
Inherited from
VGCoverride_status
EpicsSignalRO:OVRD_ON_RBVEpics Readback on Override mode
omitted
Inherited from
VGCoverride_force_open
:FORCE_OPNEpics Command to force open the valve inoverride mode
omitted
Inherited from
VGCstate
EpicsSignalRO:STATE_RBVValve state
normal
Inherited from
VGCopen_limit
EpicsSignalRO:OPN_DI_RBVOpen limit switch digital input
hinted
Inherited from
VGCclosed_limit
EpicsSignalRO:CLS_DI_RBVClosed limit switch digital input
hinted
Inherited from
VGCdiff_press_ok
EpicsSignalRO:DP_OK_RBVDifferential pressure interlock ok
normal
Inherited from
VGCext_ilk_ok
EpicsSignalRO:EXT_ILK_OK_RBVExternal interlock ok
normal
Inherited from
VGCat_vac_setpoint
:AT_VAC_SPAT VAC Set point value
config
Inherited from
VGCsetpoint_hysterisis
:AT_VAC_HYSAT VAC Hysteresis
config
Inherited from
VGCat_vac
EpicsSignalRO:AT_VAC_RBVat vacuum setpoint is reached
normal
Inherited from
VGCerror
EpicsSignalRO:ERROR_RBVError Present
normal
Inherited from
VGCmps_state
EpicsSignalRO:MPS_FAULT_OK_RBVindividual valve MPS state for debugging
omitted
Inherited from
VGCinterlock_device_upstream
EpicsSignalRO:ILK_DEVICE_US_RBVUpstream vacuum device used forinterlocking this valve
config
Inherited from
VGCinterlock_device_downstream
EpicsSignalRO:ILK_DEVICE_DS_RBVDownstream vacuum device used forinterlocking this valve
config
Inherited from
VGCMethods
- calc_lightpath_state(open_limit: int, closed_limit: int) LightpathState
Callback for updating inserted/removed for lightpath.
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- get_lightpath_state(use_cache: bool = True) LightpathState
Return the current LightpathState
- Returns:
LightpathState – a dataclass containing the Lightpath state
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind
- lightpath_cpts = ['open_limit', 'closed_limit']
- md