pcdsdevices.lasers.dicon.DiconSwitch
- class pcdsdevices.lasers.dicon.DiconSwitch(*args, **kwargs)
Class for controlling the DiCon fiber matrix switch.
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
chan1
EpicsSignal:getChan1normal
chan2
EpicsSignal:getChan2normal
chan3
EpicsSignal:getChan3normal
chan4
EpicsSignal:getChan4normal
chan5
EpicsSignal:getChan5normal
chan6
EpicsSignal:getChan6normal
chan7
EpicsSignal:getChan7normal
chan8
EpicsSignal:getChan8normal
version
EpicsSignalRO:getVersconfig
error_str
EpicsSignalRO:ErrStrconfig
error_num
EpicsSignalRO:ErrorNumconfig
reset
EpicsSignal:resetomitted
Methods
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind