pcdsdevices.mpod_apalis.MPODApalisModule4Channel
- class pcdsdevices.mpod_apalis.MPODApalisModule4Channel(*args, **kwargs)
MPODApalis 4 channel Module Object.
- Parameters:
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
voltage_ramp_speed
EpicsSignal:VoltageRampSpeedMPOD module Voltage Ramp Rate [%/sec*Vnom]
normal
Inherited from
MPODApalisModulecurrent_ramp_speed
EpicsSignal:CurrentRampSpeedMPOD module current Ramp Rate [%/sec*Inom]
normal
Inherited from
MPODApalisModuletemperature
EpicsSignalRO:TemperatureMPOD Temperature [C]
normal
Inherited from
MPODApalisModulefaults
EpicsSignal:isEventActiveClears all MPOD module faults
normal
Inherited from
MPODApalisModulec0
:C0normal
c1
:C1normal
c2
:C2normal
c3
:C3normal
Methods
- clear_faults()
Clears all module faults
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- set_current_ramp_speed(ramp_speed)
Set the current ramp speed in %/sec*Inom.
It sets the current ramp speed for the entire card.
- Parameters:
ramp_speed (number) – Current ramp speed [%/sec*Vnom].
- set_voltage_ramp_speed(ramp_speed)
Set the voltage ramp speed in %/sec*Vnom.
It sets the voltage ramp speed for the entire card.
- Parameters:
ramp_speed (number) – Voltage rise rate [%/sec*Vnom].
- stage_group_instances() Iterator[OphydObject]
Yields an iterator of subdevices that should be staged.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind