pcdsdevices.pump.Navigator
- class pcdsdevices.pump.Navigator(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)
Class for Navigator Pump controlled via serial.
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
run
EpicsSignal:RUNomitted
Inherited from
AgilentSerialconfig
EpicsSignal:CONFIGomitted
Inherited from
AgilentSerialsoftstart
EpicsSignal:SOFTSTARTomitted
Inherited from
AgilentSerialsp_type
EpicsSignal:SP_TYPEomitted
Inherited from
AgilentSerialsp_calcdis
EpicsSignal:SP_CALCDISomitted
Inherited from
AgilentSerialsp_dis
EpicsSignal:SP_DISomitted
Inherited from
AgilentSerialsp_writeval
EpicsSignal:SP_WRITEVALomitted
Inherited from
AgilentSerialsp_freq
EpicsSignal:SP_FREQomitted
Inherited from
AgilentSerialsp_current
EpicsSignal:SP_CURRENTomitted
Inherited from
AgilentSerialsp_time
EpicsSignalRO:SP_TIME_RBVomitted
Inherited from
AgilentSerialsp_delay
EpicsSignal:SP_DELAYomitted
Inherited from
AgilentSerialsp_polarity
EpicsSignal:SP_POLARITYomitted
Inherited from
AgilentSerialsp_hys
EpicsSignal:SP_HYSomitted
Inherited from
AgilentSerialwater_cooling
EpicsSignal:WATER_COOLINGnormal
Inherited from
AgilentSerialactive_stop
EpicsSignal:ACTIVE_STOPnormal
Inherited from
AgilentSerialinterlock_type
EpicsSignal:INTERLOCK_TYPEomitted
Inherited from
AgilentSerialao_type
EpicsSignal:AO_TYPEomitted
Inherited from
AgilentSerialrot_freq
EpicsSignal:ROT_FREQnormal
Inherited from
AgilentSerialvent_valve
EpicsSignal:VENT_VALVEomitted
Inherited from
AgilentSerialvent_valve_operation
EpicsSignal:VENT_VALVE_OPERATIONomitted
Inherited from
AgilentSerialvent_valve_delay
EpicsSignal:VENT_VALVE_DELAYomitted
Inherited from
AgilentSerialvent_valve_raw
EpicsSignal:VENT_VALVE_RAWomitted
Inherited from
AgilentSerialpump_current
EpicsSignalRO:PUMP_CURRENT_RBVomitted
Inherited from
AgilentSerialpump_voltage
EpicsSignalRO:PUMP_VOLTAGE_RBVnormal
Inherited from
AgilentSerialpump_power
EpicsSignalRO:PUMP_POWER_RBVnormal
Inherited from
AgilentSerialpump_drive_freq
EpicsSignalRO:PUMP_DRIVE_FREQ_RBVnormal
Inherited from
AgilentSerialpump_temp
EpicsSignalRO:PUMP_TEMP_RBVnormal
Inherited from
AgilentSerialpump_status
EpicsSignalRO:PUMP_STATUS_RBVnormal
Inherited from
AgilentSerialpump_error
EpicsSignalRO:PUMP_ERROR_RBVnormal
Inherited from
AgilentSeriallow_speed
EpicsSignalRO:LOW_SPEED_RBVomitted
low_speed_freq
EpicsSignalRO:LOW_SPEED_FREQ_RBVomitted
sp_power
EpicsSignalRO:SP_POWER_RBVomitted
sp_normal
EpicsSignalRO:SP_NORMAL_RBVomitted
sp_pressure
EpicsSignalRO:SP_PRESSURE_RBVomitted
vent_open_time
EpicsSignalRO:VENT_OPEN_TIME_RBVomitted
vent_open_time_raw
EpicsSignalRO:VENT_OPEN_TIME_RAW_RBVomitted
power_limit
EpicsSignalRO:POWER_LIMIT_RBVomitted
gas_load_type
EpicsSignalRO:GAS_LOAD_TYPE_RBVomitted
press_read_corr
EpicsSignalRO:PRESS_READ_CORR_RBVomitted
sp_press_unit
EpicsSignalRO:SP_PRESS_UNIT_RBVomitted
sp_write_press_unit
EpicsSignalRO:SP_WRITE_PRESS_UNIT_RBVomitted
stop_speed_reading
EpicsSignalRO:STOP_SPEED_READING_RBVomitted
ctrl_heatsink_temp
EpicsSignalRO:CTRL_HEATSINK_TEMP_RBVomitted
ctrl_air_temp
EpicsSignalRO:CTRL_AIR_TEMP_RBVomitted
Methods
- configure(d: Dict[str, Any]) → Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() → OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- read() → OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() → OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() → StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind