pcdsdevices.valve.VCN_VAT590
- class pcdsdevices.valve.VCN_VAT590(*args, **kwargs)
- VCN_VAT590 = Variable Controlled Needle Valve using the VAT590 - VAT590 = series 590 valve from the company, VAT VAT = company that manufactures vacuum valves, among other things - This has different PVs than the normal VCN class. - This corresponds to the ST_VCN_VAT590 and ST_VAT590_STATUS data types in the lcls-twincat-vacuum library. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - pos_raw - POS_RAW- Position readback - hinted - pres_torr - PRES_TORR- Pressure readback in torr units - hinted - pres_raw - PRES_RAW- Pressure readback - normal - pos_sp - POS_SP- Position setpoint readback - normal - pres_sp - PRES_SP- Pressure setpoint readback - normal - ilk_ok - ILK_OK- Interlock bit status - normal - pos_req - POS_REQ- Requested position (0.0-100%) - config - pres_req - PRES_REQ- Requested pressure in torr units - config - state - STATE- Valve control mode - config - pos_limit - POS_LIMIT- Percentage upper limit on valve open - config - pres_set_limit - PRES_SET_LIMIT- Upper limit for pressure control - config - pres_rdbk_limit - PRES_RDBK_LIMIT- Upper limit for pressure reading before valve close - config - pres_sens - PRES_SENS- Select pressure sensor - config - rem_ctrl - REM_CTRL- Select remote control mode - config - zero - ZERO- Activate zero function bit - config - status - normal - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns:
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns:
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - post_elog_status()
- Post device status to the primary elog, if possible. 
 - read() OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - screen()
- Open a screen for controlling the device. - Default behavior is the typhos screen, but this method can be overridden for more specialized screens. 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns:
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - hints
 - kind