pcdsdevices.attenuator.SXRGasAtt
================================

.. currentmodule:: pcdsdevices.attenuator

.. autoclass:: SXRGasAtt

    
    
    .. list-table:: Ophyd Device Components
        :header-rows: 1
        :widths: auto

        * - Attribute
          - Class
          - Suffix
          - Docs
          - Kind
          - Notes
    
        * - transmission
          - :class:`~ophyd.signal.EpicsSignal`
          - ``:TRANS_RBV``
          - Transmission
          - hinted
          - 
    
        * - arb_req
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:TRANS_REQ_RBV``
          - Requested transmission
          - hinted
          - 
    
        * - pressure
          - :class:`~ophyd.signal.EpicsSignal`
          - ``:GCM:82:PRESS_RBV``
          - Pressure
          - hinted
          - 
    
        * - pressure_setpoint_rbv
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:CNTRL:SP_RBV``
          - Pressure setpoint
          - omitted
          - 
    
        * - mode
          - :class:`~ophyd.signal.EpicsSignal`
          - ``:MODE_RBV``
          - PMPS mode
          - hinted
          - 
    
        * - control_enable
          - :class:`~ophyd.signal.EpicsSignal`
          - ``:CNTRL:ON_RBV``
          - 
          - hinted
          - 
    
        * - pressure_control_enable
          - :class:`~ophyd.signal.EpicsSignal`
          - ``:MODE:PressureControl_RBV``
          - Pressure control mode
          - hinted
          - 
    
        * - gas_type
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:GAS_TYPE_RBV``
          - Selected gas
          - hinted
          - 
    
        * - at_target
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:AtTarget_RBV``
          - At target
          - hinted
          - 
    
        * - moving
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:Moving_RBV``
          - Moving
          - hinted
          - 
    
        * - gas_att_ok
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:OK_RBV``
          - Ok
          - hinted
          - 
    
        * - transmission_setpoint_rbv
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:TRANS_SP_RBV``
          - Transmission setpoint
          - omitted
          - 
    
        * - pressure_control_valve
          - :class:`~ophyd.signal.EpicsSignalRO`
          - ``:VCN:70:POS_REQ_RBV``
          - Requested position
          - omitted
          - 
    
        * - valve_n2
          - :class:`~pcdsdevices.valve.VVC`
          - ``:VVC:72``
          - Valve n2
          - hinted
          - 
    
        * - valve_ar
          - :class:`~pcdsdevices.valve.VVC`
          - ``:VVC:71``
          - Valve ar
          - hinted
          - 
    
        * - valve_pressure_control
          - :class:`~pcdsdevices.valve.VCN`
          - ``:VCN:70``
          - Pressure control valve
          - omitted
          - 
    

    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    

    
    

    
    
    .. rubric:: Methods

    
    .. automethod:: configure
    .. automethod:: describe
    .. automethod:: get
    .. automethod:: post_elog_status
    .. automethod:: read
    .. automethod:: read_configuration
    .. automethod:: screen
    .. automethod:: setup_mode
    .. automethod:: stage_group_instances
    .. automethod:: status
    .. automethod:: stop
    .. automethod:: summary
    .. automethod:: trigger
    
    

    
    
    .. rubric:: Attributes

    
    .. autoattribute:: configuration_attrs
    .. autoattribute:: connected
    .. autoattribute:: hints
    .. autoattribute:: kind
    .. autoattribute:: needs_parent
    .. autoattribute:: stage_group
    .. autoattribute:: subscriptions