pcdsdevices.spectrometer.Mono
- class pcdsdevices.spectrometer.Mono(*args, **kwargs)
L2S-I NEH 2.X Monochromator
Axilon mechatronic design with LCLS-II Beckhoff motion architecture.
Parameters:
- preifxstr
Base PV for the monochromator
- namestr
Alias for the device
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
lightpath_summary
omitted
Inherited from
LightpathMixingrating_states
:GRATING:STATEmono grating states g_h
normal
m_pi
:MMS:M_PImirror pitch [urad]
normal
g_pi
:MMS:G_PIgrating pitch [urad]
normal
m_h
:MMS:M_Hmirror horizontal [um]
normal
g_h
:MMS:G_Hgrating horizontal [um]
normal
sd_v
:MMS:SD_Vscrewdriver vertical (in/out) [um]
normal
sd_rot
:MMS:SD_ROTscrewdriver rotation [urad]
normal
m_pi_up_enc
:ENC:M_PI:02mirror pitch upstream encoder [urad]
omitted
g_pi_up_enc
:ENC:G_PI:02grating pitch upstream encoder [urad]
omitted
m_pi_enc_rms
:MMS:M_PI:ENCDIFF:STATS:RMSmirror pitch encoder RMS deviation [nrad]
normal
g_pi_enc_rms
:MMS:G_PI:ENCDIFF:STATS:RMSgrating pitch encoder RMS deviation [nrad]
normal
led_power_1
:LED:01:PWRLED power supply controls.
config
led_power_2
:LED:02:PWRLED power supply controls.
config
led_power_3
:LED:03:PWRLED power supply controls.
config
cool_flow1
:FWM:1flow meter 1
normal
cool_flow2
:FWM:2flow meter 2
normal
cool_press
:PRSM:1pressure meter 1
normal
grating_temp_1
:RTD:01:TEMP[deg C]
normal
grating_temp_2
:RTD:02:TEMP[deg C]
normal
grating_temp_3
:RTD:03:TEMP[deg C]
normal
grating_temp_4
:RTD:04:TEMP[deg C]
normal
grating_mask_temp_1
:RTD:05:TEMP[deg C]
normal
grating_mask_temp_2
:RTD:06:TEMP[deg C]
normal
grating_mask_temp_3
:RTD:07:TEMP[deg C]
normal
grating_mask_temp_4
:RTD:08:TEMP[deg C]
normal
mirror_mask_temp
:RTD:09:TEMP[deg C]
normal
mirror_cooling_temp
:RTD:11:TEMP[deg C]
normal
exit_mask_right_temp
:RTD:10:TEMP[deg C]
normal
exit_mask_left_temp
:RTD:12:TEMP[deg C]
normal
Methods
- calc_lightpath_state(**kwargs) LightpathState
Create and return a LightpathState object containing information needed for lightpath, given a set of signal values
kwargs should be the same as the signal names provided in
lightpath_cptsDevice logic goes here.
- Returns:
LightpathState – a dataclass containing the Lightpath state
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- get_lightpath_state(use_cache: bool = True) LightpathState
Return the current LightpathState
- Returns:
LightpathState – a dataclass containing the Lightpath state
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- stage_group_instances() Iterator[OphydObject]
Yields an iterator of subdevices that should be staged.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind
- lightpath_cpts = ['m_pi.user_readback']
- md
- needs_parent: list[type[OphydObject]] = [<class 'ophyd.signal.AttributeSignal'>, <class 'ophyd.signal.DerivedSignal'>, <class 'ophyd.areadetector.plugins.PluginBase'>, <class 'ophyd.pseudopos.PseudoSingle'>, <class 'pcdsdevices.signal.PVStateSignal'>, <class 'pcdsdevices.signal.AggregateSignal'>]
- transmission = 1