pcdsdevices.lasers.btps.DestinationConfig
- class pcdsdevices.lasers.btps.DestinationConfig(prefix: str, destination_pos: DestinationPosition, **kwargs)
- BTPS per-destination configuration settings and state. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - BTPS:Name- Destination name - normal - exit_valve_ready - BTPS:ExitValveReady- Exit valve is open and ready - normal - yields_control - BTPS:YieldsControl- Destination using beam or yielding control - normal - ls1 - LS1:- Settings for source LS1 (bay 1) to this destination - normal - ls3 - LS3:- Settings for source LS3 (bay 2 1um) to this destination - normal - ls4 - LS4:- Settings for source LS4 (bay 2 800m) to this destination - normal - ls5 - LS5:- Settings for source LS5 (bay 3 800nm) to this destination - normal - ls6 - LS6:- Settings for source LS6 (bay 3 1um) to this destination - normal - ls8 - LS8:- Settings for source LS8 (bay 4) to this destination - normal - exit_valve - VGC:01- Destination exit valve - normal - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns:
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns:
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - post_elog_status()
- Post device status to the primary elog, if possible. 
 - read() OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - screen()
- Open a screen for controlling the device. - Default behavior is the typhos screen, but this method can be overridden for more specialized screens. 
 - classmethod set_defaults(*, connection_timeout=10.0)
- Set class-wide defaults for device communications - This may be called only before any instances of Device are made. - This setting applies to the class it is called on and all its subclasses. For example, - >>> Device.set_defaults(...) - will apply to any Device subclass. - Parameters:
- connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC. 
- Raises:
- RuntimeError – If called after - EpicsSignalBasehas been instantiated for the first time.
 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns:
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - connection_timeout
 - hints
 - kind
 - sources
- returns: Dict[SourcePosition, SourceToDestinationConfig] 
 - destination_pos: btms.DestinationPosition