pcdsdevices.valve.VRCNO
- class pcdsdevices.valve.VRCNO(*args, input_branches=[], output_branches=[], **kwargs)
- VRCNO = Valve with Readback and Control, Normally Open - This is a valve that defaults to the “open” state and includes controllable elements. - It corresponds with ST_VRC_NO in the lcls-twincat-vacuum library, but it also includes elements defined in ST_ValveBase, and it doesn’t use all of the PVs defined in the struct. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - lightpath_summary - omitted - Inherited from - LightpathMixin- close_command - :CLS_SW- Epics command to close valve - normal - Inherited from - VVCNO- override_force_close - :FORCE_CLS- Epics Command for close the valve in override mode - omitted - Inherited from - VVCNO- override_on - :OVRD_ON- Epics Command to set/reset Override mode - omitted - Inherited from - VVCNO- close_ok - EpicsSignalRO- :CLS_OK_RBV- used for normally open valves - normal - Inherited from - VVCNO- close_do - EpicsSignalRO- :CLS_DO_RBV- PLC Output to close valve - normal - Inherited from - VVCNO- state - EpicsSignalRO- :STATE_RBV- Valve state - normal - error_reset - :ALM_RST- Reset Error state to valid by toggling this - normal - open_limit - EpicsSignalRO- :OPN_DI_RBV- Open limit switch digital input - hinted - closed_limit - EpicsSignalRO- :CLS_DI_RBV- Closed limit switch digital input - hinted - Methods - calc_lightpath_state(open_limit: int, closed_limit: int)
- Callback for updating inserted/removed for lightpath. 
 - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns:
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns:
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - get_lightpath_state(use_cache: bool = True) LightpathState
- Return the current LightpathState - Returns:
- LightpathState – a dataclass containing the Lightpath state 
 
 - read() OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - classmethod set_defaults(*, connection_timeout=10.0)
- Set class-wide defaults for device communications - This may be called only before any instances of Device are made. - This setting applies to the class it is called on and all its subclasses. For example, - >>> Device.set_defaults(...) - will apply to any Device subclass. - Parameters:
- connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC. 
- Raises:
- RuntimeError – If called after - EpicsSignalBasehas been instantiated for the first time.
 
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns:
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - close_override
- Fixes potential API breaks with old name 
 - configuration_attrs
 - connected
 - connection_timeout
 - hints
 - kind
 - lightpath_cpts = ['open_limit', 'closed_limit']
 - md