pcdsdevices.pdu.TripplitePDU
- class pcdsdevices.pdu.TripplitePDU(prefix, num_channels, name=None, **kwargs)
Class to define a Tripplite PDU.
- Parameters:
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
tower_name
EpicsSignal:setDeviceNamehinted
location
EpicsSignal:setDeviceLocationhinted
status
EpicsSignalRO:getDeviceStatushinted
num_inputs
EpicsSignalRO:getPduIdentNumInputshinted
num_outputs
EpicsSignalRO:getPduIdentNumOutputshinted
num_outlets
EpicsSignalRO:getPduIdentNumOutletshinted
num_groups
EpicsSignalRO:getPduIdentNumOutletGroupshinted
num_phases
EpicsSignalRO:getPduIdentNumPhaseshinted
num_circuits
EpicsSignalRO:getPduIdentNumCircuitshinted
num_breakers
EpicsSignalRO:getPduIdentNumBreakershinted
num_heatsinks
EpicsSignalRO:getPduIdentNumHeatsinkshinted
input_f
EpicsSignalRO:getPduInputPhaseFrequencyhinted
input_v
EpicsSignalRO:getPduInputPhaseVoltagehinted
input_v_min
EpicsSignalRO:getPduInputPhaseVoltageMinhinted
input_v_max
EpicsSignalRO:getPduInputPhaseVoltageMaxhinted
output_f
EpicsSignalRO:getPduOutputFrequencyhinted
output_v
EpicsSignalRO:getPduOutputVoltagehinted
output_p
EpicsSignalRO:getPduOutputActivePowerhinted
output_c
EpicsSignalRO:getPduOutputCurrenthinted
output_c_min
EpicsSignalRO:getPduOutputCurrentMinhinted
output_c_max
EpicsSignalRO:getPduOutputCurrentMaxhinted
channels_on
EpicsSignal:setPduControlPduOnhinted
channels_off
EpicsSignal:setPduControlPduOffhinted
channels_reboot
EpicsSignal:setPduControlPduReboothinted
Methods
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- classmethod set_defaults(*, connection_timeout=10.0)
Set class-wide defaults for device communications
This may be called only before any instances of Device are made.
This setting applies to the class it is called on and all its subclasses. For example,
>>> Device.set_defaults(...)
will apply to any Device subclass.
- Parameters:
connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC.
- Raises:
RuntimeError – If called after
EpicsSignalBasehas been instantiated for the first time.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- connection_timeout
- hints
- kind