pcdsdevices.pdu.TripplitePDU8
- class pcdsdevices.pdu.TripplitePDU8(prefix, name=None, **kwargs)
8-channel Tripplite PDU with static channel definitions for Typhos
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
tower_name
EpicsSignal:setDeviceNamehinted
Inherited from
TripplitePDUlocation
EpicsSignal:setDeviceLocationhinted
Inherited from
TripplitePDUstatus
EpicsSignalRO:getDeviceStatushinted
Inherited from
TripplitePDUnum_inputs
EpicsSignalRO:getPduIdentNumInputshinted
Inherited from
TripplitePDUnum_outputs
EpicsSignalRO:getPduIdentNumOutputshinted
Inherited from
TripplitePDUnum_outlets
EpicsSignalRO:getPduIdentNumOutletshinted
Inherited from
TripplitePDUnum_groups
EpicsSignalRO:getPduIdentNumOutletGroupshinted
Inherited from
TripplitePDUnum_phases
EpicsSignalRO:getPduIdentNumPhaseshinted
Inherited from
TripplitePDUnum_circuits
EpicsSignalRO:getPduIdentNumCircuitshinted
Inherited from
TripplitePDUnum_breakers
EpicsSignalRO:getPduIdentNumBreakershinted
Inherited from
TripplitePDUnum_heatsinks
EpicsSignalRO:getPduIdentNumHeatsinkshinted
Inherited from
TripplitePDUinput_f
EpicsSignalRO:getPduInputPhaseFrequencyhinted
Inherited from
TripplitePDUinput_v
EpicsSignalRO:getPduInputPhaseVoltagehinted
Inherited from
TripplitePDUinput_v_min
EpicsSignalRO:getPduInputPhaseVoltageMinhinted
Inherited from
TripplitePDUinput_v_max
EpicsSignalRO:getPduInputPhaseVoltageMaxhinted
Inherited from
TripplitePDUoutput_f
EpicsSignalRO:getPduOutputFrequencyhinted
Inherited from
TripplitePDUoutput_v
EpicsSignalRO:getPduOutputVoltagehinted
Inherited from
TripplitePDUoutput_p
EpicsSignalRO:getPduOutputActivePowerhinted
Inherited from
TripplitePDUoutput_c
EpicsSignalRO:getPduOutputCurrenthinted
Inherited from
TripplitePDUoutput_c_min
EpicsSignalRO:getPduOutputCurrentMinhinted
Inherited from
TripplitePDUoutput_c_max
EpicsSignalRO:getPduOutputCurrentMaxhinted
Inherited from
TripplitePDUchannels_on
EpicsSignal:setPduControlPduOnhinted
Inherited from
TripplitePDUchannels_off
EpicsSignal:setPduControlPduOffhinted
Inherited from
TripplitePDUchannels_reboot
EpicsSignal:setPduControlPduReboothinted
Inherited from
TripplitePDUchannel1
normal
channel2
normal
channel3
normal
channel4
normal
channel5
normal
channel6
normal
channel7
normal
channel8
normal
Methods
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- classmethod set_defaults(*, connection_timeout=10.0)
Set class-wide defaults for device communications
This may be called only before any instances of Device are made.
This setting applies to the class it is called on and all its subclasses. For example,
>>> Device.set_defaults(...)
will apply to any Device subclass.
- Parameters:
connection_timeout (float, optional) – Time (seconds) allocated for establishing a connection with the IOC.
- Raises:
RuntimeError – If called after
EpicsSignalBasehas been instantiated for the first time.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- connection_timeout
- hints
- kind