pcdsdevices.gauge.GFSPLC
- class pcdsdevices.gauge.GFSPLC(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)
- Class for a fast shutter sensor gauge controlled by PLC. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - pressure - EpicsSignalRO- :PRESS_RBV- gauge pressure reading - hinted - Inherited from - GCCPLC- gauge_at_vac - EpicsSignalRO- :AT_VAC_RBV- gauge is at VAC - normal - Inherited from - GCCPLC- pressure_ok - EpicsSignalRO- :PRESS_OK_RBV- pressure reading ok - normal - Inherited from - GCCPLC- at_vac_setpoint - :VAC_SP- At vacuum setpoint for all gauges - config - Inherited from - GCCPLC- state - EpicsSignalRO- :STATE_RBV- state of the gauge - hinted - Inherited from - GCCPLC- high_voltage_on - :HV_SW- command to switch the high voltage on - normal - Inherited from - GCCPLC- high_voltage_disable - EpicsSignalRO- :HV_DIS_DO_RBV- enables the high voltage on the cold cathode gauge - normal - Inherited from - GCCPLC- protection_setpoint - :PRO_SP- Protection setpoint for ion gauges at which the gauge turns off - normal - Inherited from - GCCPLC- setpoint_hysterisis - :SP_HYS- Protection setpoint hysteresis - config - Inherited from - GCCPLC- interlock_ok - EpicsSignalRO- :ILK_OK_RBV- Interlock is ok - normal - Inherited from - GCCPLC- auto_on - :Auto_On- Setting to automatically turn on the gauge when thereference gauge pressure is below protection setpoint - config - Inherited from - GCCPLC- autoOn_countdown - EpicsSignalRO- :AutoOn_timer_RBV- timer count down to turn on the gauge - normal - Inherited from - GCCPLC- fault_setpoint_FS - EpicsSignalRO- :PSTATSPRBCK_FS- Vacuum fault setpoint for Fast shutter valve - config - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - read() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() ophyd.status.StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - hints
 - kind