pcdsdevices.gauge.GaugeSerialGPI
- class pcdsdevices.gauge.GaugeSerialGPI(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)
- Class for Pirani Vacuum Gauges controlled via serial. - Ophyd Device Components - Attribute - Class - Suffix - Docs - Kind - Notes - gastype - EpicsSignal- :GASTYPE- omitted - Inherited from - GaugeSerial- gastypedes - EpicsSignal- :GASTYPEDES- omitted - Inherited from - GaugeSerial- hystsprbck_1 - EpicsSignalRO- :HYSTSPRBCK_1_RBV- omitted - Inherited from - GaugeSerial- hystsprbck_2 - EpicsSignalRO- :HYSTSPRBCK_2_RBV- omitted - Inherited from - GaugeSerial- p - EpicsSignal- :P- omitted - Inherited from - GaugeSerial- padel - EpicsSignal- :PADEL- omitted - Inherited from - GaugeSerial- plog - EpicsSignal- :PLOG- omitted - Inherited from - GaugeSerial- pmon - EpicsSignal- :PMON- omitted - Inherited from - GaugeSerial- pmonraw - EpicsSignal- :PMONRAW- omitted - Inherited from - GaugeSerial- pstat_1 - EpicsSignal- :PSTAT_1- omitted - Inherited from - GaugeSerial- pstat_2 - EpicsSignal- :PSTAT_2- omitted - Inherited from - GaugeSerial- pstat_calc - EpicsSignal- :PSTAT_CALC- omitted - Inherited from - GaugeSerial- pstat_sum - EpicsSignal- :PSTAT_SUM- omitted - Inherited from - GaugeSerial- pstatdirdes_1 - EpicsSignal- :PSTATDIRDES_1- omitted - Inherited from - GaugeSerial- pstatdirdes_2 - EpicsSignal- :PSTATDIRDES_2- omitted - Inherited from - GaugeSerial- pstatenable_1 - EpicsSignal- :PSTATENABLE_1- omitted - Inherited from - GaugeSerial- pstatenable_2 - EpicsSignal- :PSTATENABLE_2- omitted - Inherited from - GaugeSerial- pstatenades_1 - EpicsSignal- :PSTATENADES_1- omitted - Inherited from - GaugeSerial- pstatenades_2 - EpicsSignal- :PSTATENADES_2- omitted - Inherited from - GaugeSerial- pstatspdes_1 - EpicsSignal- :PSTATSPDES_1- omitted - Inherited from - GaugeSerial- pstatspdes_2 - EpicsSignal- :PSTATSPDES_2- omitted - Inherited from - GaugeSerial- pstatspdir_1 - EpicsSignal- :PSTATSPDIR_1- omitted - Inherited from - GaugeSerial- pstatspdir_2 - EpicsSignal- :PSTATSPDIR_2- omitted - Inherited from - GaugeSerial- pstatsprbck_1 - EpicsSignalRO- :PSTATSPRBCK_1_RBV- omitted - Inherited from - GaugeSerial- pstatsprbck_2 - EpicsSignalRO- :PSTATSPRBCK_2_RBV- omitted - Inherited from - GaugeSerial- state - EpicsSignal- :STATE- omitted - Inherited from - GaugeSerial- statedes - EpicsSignal- :STATEDES- omitted - Inherited from - GaugeSerial- staterbck - EpicsSignalRO- :STATERBCK_RBV- omitted - Inherited from - GaugeSerial- status_rs - EpicsSignal- :STATUS_RS- omitted - Inherited from - GaugeSerial- status_rs_calc1 - EpicsSignal- :STATUS_RS_CALC1- omitted - Inherited from - GaugeSerial- status_rs_calc2 - EpicsSignal- :STATUS_RS_CALC2- omitted - Inherited from - GaugeSerial- status_rscalc - EpicsSignal- :STATUS_RSCALC- omitted - Inherited from - GaugeSerial- status_rscalc2 - EpicsSignal- :STATUS_RSCALC2- omitted - Inherited from - GaugeSerial- status_rsmon - EpicsSignal- :STATUS_RSMON- omitted - Inherited from - GaugeSerial- status_rsout - EpicsSignal- :STATUS_RSOUT- omitted - Inherited from - GaugeSerial- atmcalib - EpicsSignal- :ATMCALIB- omitted - atmcalibdes - EpicsSignal- :ATMCALIBDES- omitted - autozero - EpicsSignalRO- :AUTOZERO_RBV- omitted - autozerodes - EpicsSignal- :AUTOZERODES- omitted - zeropr - EpicsSignal- :ZEROPR- omitted - Methods - configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
- Configure the device for something during a run - This default implementation allows the user to change any of the - configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters
- d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict. 
- Returns
- (old, new) tuple of dictionaries 
- Where old and new are pre- and post-configure configuration states. 
 
 
 - describe() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Provide schema and meta-data for - read().- This keys in the - OrderedDictthis method returns must match the keys in the- OrderedDictreturn by- read().- This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc. - Returns
- data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the - event_model.event_descriptor.data_keyschema.
 
 - get(**kwargs)
- Get the value of all components in the device - Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included. 
 - read() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Read data from the device. - This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in - trigger().- The - OrderedDictreturned by this method must have identical keys (in the same order) as the- OrderedDictreturned by- describe().- By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in - bluesky.- The values in the ordered dictionary must be dict (-likes) with the keys - {'value', 'timestamp'}. The- 'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns
- data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys - {'value', 'timestamp'}
 
 - read_configuration() ophyd.device.OrderedDictType[str, Dict[str, Any]]
- Dictionary mapping names to value dicts with keys: value, timestamp - To control which fields are included, change the Component kinds on the device, or modify the - configuration_attrslist.
 - stop(*, success=False)
- Stop the Device and all (instantiated) subdevices 
 - summary()
 - trigger() ophyd.status.StatusBase
- Trigger the device and return status object. - This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device. - If there is an appreciable time between triggering the device and it being able to be read (via the - read()method) then this method is also responsible for arranging that the- StatusBaseobject returned by this method is notified when the device is ready to be read.- If there is no delay between triggering and being readable, then this method must return a - StatusBaseobject which is already completed.- Returns
- status (StatusBase) – - StatusBaseobject which will be marked as complete when the device is ready to be read.
 
 - Attributes - configuration_attrs
 - connected
 - hints
 - kind