pcdsdevices.valve.VCN_VAT590
- class pcdsdevices.valve.VCN_VAT590(*args, **kwargs)
VCN_VAT590 = Variable Controlled Needle Valve using the VAT590
VAT590 = series 590 valve from the company, VAT VAT = company that manufactures vacuum valves, among other things
This has different PVs than the normal VCN class.
This corresponds to the ST_VCN_VAT590 and ST_VAT590_STATUS data types in the lcls-twincat-vacuum library.
Ophyd Device Components Attribute
Class
Suffix
Docs
Kind
Notes
pos_raw
POS_RAWPosition readback
hinted
pres_torr
PRES_TORRPressure readback in torr units
hinted
pres_raw
PRES_RAWPressure readback
normal
pos_sp
POS_SPPosition setpoint readback
normal
pres_sp
PRES_SPPressure setpoint readback
normal
ilk_ok
ILK_OKInterlock bit status
normal
pos_req
POS_REQRequested position (0.0-100%)
config
pres_req
PRES_REQRequested pressure in torr units
config
state
STATEValve control mode
config
pos_limit
POS_LIMITPercentage upper limit on valve open
config
pres_set_limit
PRES_SET_LIMITUpper limit for pressure control
config
pres_rdbk_limit
PRES_RDBK_LIMITUpper limit for pressure reading before valve close
config
pres_sens
PRES_SENSSelect pressure sensor
config
rem_ctrl
REM_CTRLSelect remote control mode
config
zero
ZEROActivate zero function bit
config
status
normal
Methods
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read().This keys in the
OrderedDictthis method returns must match the keys in theOrderedDictreturn byread().This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_keyschema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger().The
OrderedDictreturned by this method must have identical keys (in the same order) as theOrderedDictreturned bydescribe().By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}. The'value'may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrslist.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()method) then this method is also responsible for arranging that theStatusBaseobject returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBaseobject which is already completed.- Returns:
status (StatusBase) –
StatusBaseobject which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind