pcdsdevices.areadetector.detectors.PCDSAreaDetectorTyphosBeamStats

class pcdsdevices.areadetector.detectors.PCDSAreaDetectorTyphosBeamStats(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)

Adds in some PVs related to beam statistics, as well as a cross hair. Primarily intended for use in the laser control system.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

manufacturer

EpicsSignalRO

Manufacturer_RBV

config

Inherited from PCDSAreaDetectorTyphosTrigger

camera_model

EpicsSignalRO

Model_RBV

normal

Inherited from PCDSAreaDetectorTyphosTrigger

sensor_size_x

EpicsSignalRO

MaxSizeX_RBV

config

Inherited from PCDSAreaDetectorTyphosTrigger

sensor_size_y

EpicsSignalRO

MaxSizeY_RBV

config

Inherited from PCDSAreaDetectorTyphosTrigger

data_type

EpicsSignalWithRBV

DataType

config

Inherited from PCDSAreaDetectorTyphosTrigger

exposure

EpicsSignalWithRBV

AcquireTime

config

Inherited from PCDSAreaDetectorTyphosTrigger

gain

EpicsSignalWithRBV

Gain

config

Inherited from PCDSAreaDetectorTyphosTrigger

num_images

EpicsSignalWithRBV

NumImages

config

Inherited from PCDSAreaDetectorTyphosTrigger

image_mode

EpicsSignalWithRBV

ImageMode

config

Inherited from PCDSAreaDetectorTyphosTrigger

trigger_mode

EpicsSignalWithRBV

TriggerMode

config

Inherited from PCDSAreaDetectorTyphosTrigger

acquisition_period

EpicsSignalWithRBV

AcquirePeriod

config

Inherited from PCDSAreaDetectorTyphosTrigger

bin_x

EpicsSignalWithRBV

BinX

config

Inherited from PCDSAreaDetectorTyphosTrigger

bin_y

EpicsSignalWithRBV

BinY

config

Inherited from PCDSAreaDetectorTyphosTrigger

region_start_x

EpicsSignalWithRBV

MinX

config

Inherited from PCDSAreaDetectorTyphosTrigger

region_size_x

EpicsSignalWithRBV

SizeX

config

Inherited from PCDSAreaDetectorTyphosTrigger

region_start_y

EpicsSignalWithRBV

MinY

config

Inherited from PCDSAreaDetectorTyphosTrigger

region_size_y

EpicsSignalWithRBV

SizeY

config

Inherited from PCDSAreaDetectorTyphosTrigger

acquire

EpicsSignal

Acquire

normal

Inherited from PCDSAreaDetectorTyphosTrigger

acquire_rbv

EpicsSignalRO

DetectorState_RBV

normal

Inherited from PCDSAreaDetectorTyphosTrigger

image_counter

EpicsSignalRO

NumImagesCounter_RBV

normal

Inherited from PCDSAreaDetectorTyphosTrigger

cam_viewer

AttributeSignal

normal

Inherited from PCDSAreaDetectorTyphosTrigger

event_code

EpicsSignalWithRBV

CamEventCode

Code to determine beam synchronization rate.

config

Inherited from PCDSAreaDetectorTyphosTrigger

event_rate

EpicsSignalRO

CamRepRate_RBV

Current rate of the incoming triggers. Determined by event_code and the accelerator state.

config

Inherited from PCDSAreaDetectorTyphosTrigger

stats_enable

EpicsSignalWithRBV

Stats2:EnableCallbacks

config

centroid_x

EpicsSignalRO

Stats2:CentroidX_RBV

normal

centroid_y

EpicsSignalRO

Stats2:CentroidY_RBV

normal

sigma_x

EpicsSignalRO

Stats2:SigmaX_RBV

normal

sigma_y

EpicsSignalRO

Stats2:SigmaY_RBV

normal

centroid_threshold

EpicsSignalWithRBV

Stats2:CentroidThreshold

config

centroid_enable

EpicsSignal

Stats2:ComputeCentroid

config

target_x

EpicsSignalWithRBV

Cross4:MinX

normal

target_y

EpicsSignalWithRBV

Cross4:MinY

normal

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

open_viewer()

Launch the python camera viewer for this camera.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Lean on open_viewer method

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})