pcdsdevices.attenuator.AttenuatorCalculator_AT2L0
- class pcdsdevices.attenuator.AttenuatorCalculator_AT2L0(prefix, *, name, **kwargs)
Solid attenuator variant from the LCLS-II XTES project.
- Parameters:
Attribute
Class
Suffix
Docs
Kind
Notes
calc_mode
EpicsSignal
:SYS:CalcMode
Floor or Ceiling calculation
config
Inherited from
AttenuatorCalculatorBase
energy_source
EpicsSignal
:SYS:EnergySource
Use beamline photon energy or custom energy?
config
Inherited from
AttenuatorCalculatorBase
energy_custom
EpicsSignal
:SYS:CustomPhotonEnergy
Custom energy to use for calculations [eV]
config
Inherited from
AttenuatorCalculatorBase
energy_actual
EpicsSignalRO
:SYS:ActualPhotonEnergy_RBV
The reported beamline photon energy [eV]
normal
Inherited from
AttenuatorCalculatorBase
actual_transmission
EpicsSignalRO
:SYS:ActualTransmission_RBV
Actual normalized transmission value
normal
Inherited from
AttenuatorCalculatorBase
actual_transmission_3omega
EpicsSignalRO
:SYS:Actual3OmegaTransmission_RBV
Actual 3 omega normalized transmission value
normal
Inherited from
AttenuatorCalculatorBase
desired_transmission
EpicsSignal
:SYS:DesiredTransmission
Desired normalized transmission value
normal
Inherited from
AttenuatorCalculatorBase
last_energy
EpicsSignalRO
:SYS:LastPhotonEnergy_RBV
The photon energy used for the previous calculation; i.e., the one that goes along with
best_config
.config
Inherited from
AttenuatorCalculatorBase
best_config
EpicsSignalRO
:SYS:BestConfiguration_RBV
The best configuration of filters for the desired transmission
normal
Inherited from
AttenuatorCalculatorBase
best_config_bitmask
EpicsSignalRO
:SYS:BestConfigurationBitmask_RBV
The best configuration of filters for the desired transmission.
normal
Inherited from
AttenuatorCalculatorBase
best_config_error
EpicsSignalRO
:SYS:BestConfigError_RBV
Desired to calculated transmission error
normal
Inherited from
AttenuatorCalculatorBase
active_config
EpicsSignalRO
:SYS:ActiveConfiguration_RBV
Where the filters are now
omitted
Inherited from
AttenuatorCalculatorBase
active_config_bitmask
EpicsSignalRO
:SYS:ActiveConfigurationBitmask_RBV
Where the filters are now (as an integer)
normal
Inherited from
AttenuatorCalculatorBase
filters_moving
EpicsSignalRO
:SYS:FiltersMoving_RBV
Filter-by-filter motion status (1 if moving)
normal
Inherited from
AttenuatorCalculatorBase
filters_moving_bitmask
EpicsSignalRO
:SYS:FiltersMovingBitmask_RBV
Filter-by-filter motion status as a bitmask
normal
Inherited from
AttenuatorCalculatorBase
run_calculation
EpicsSignal
:SYS:Run
Start the calculation
config
Inherited from
AttenuatorCalculatorBase
apply_config
EpicsSignal
:SYS:ApplyConfiguration
Apply the best configuration (i.e., move the filters)
config
Inherited from
AttenuatorCalculatorBase
moving
EpicsSignalRO
:SYS:Moving_RBV
Are filters being moved in/out?
config
Inherited from
AttenuatorCalculatorBase
filters (DDC)
Filters
(See below)
normal
Attribute
Class
Suffix
Docs
Kind
Notes
filter_02
:FILTER:02:
normal
filter_03
:FILTER:03:
normal
filter_04
:FILTER:04:
normal
filter_05
:FILTER:05:
normal
filter_06
:FILTER:06:
normal
filter_07
:FILTER:07:
normal
filter_08
:FILTER:08:
normal
filter_09
:FILTER:09:
normal
filter_10
:FILTER:10:
normal
filter_11
:FILTER:11:
normal
filter_12
:FILTER:12:
normal
filter_13
:FILTER:13:
normal
filter_14
:FILTER:14:
normal
filter_15
:FILTER:15:
normal
filter_16
:FILTER:16:
normal
filter_17
:FILTER:17:
normal
filter_18
:FILTER:18:
normal
filter_19
:FILTER:19:
normal
Methods
- calculate(transmission, *, energy=None, use_floor=True)
Calculate a blade configuration given a desired transmission value.
If
energy
is not specified, this method defaults to using the current L-line photon energy, as reported by the Photon Machine Protection System:PMPS:LFE:PE:UND:CurrentPhotonEnergy_RBV
.
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs
. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read()
.This keys in the
OrderedDict
this method returns must match the keys in theOrderedDict
return byread()
.This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_key
schema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- get_active_config(**kwargs)
Get the active filter configuration.
- get_best_config(**kwargs)
Get the calculated (best) filter configuration.
- get_moving_status(**kwargs)
Get the filter motion status.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger()
.The
OrderedDict
returned by this method must have identical keys (in the same order) as theOrderedDict
returned bydescribe()
.By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky
.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}
. The'value'
may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrs
list.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()
method) then this method is also responsible for arranging that theStatusBase
object returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBase
object which is already completed.- Returns:
status (StatusBase) –
StatusBase
object which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- first_filter = 2
- hints
- kind
- num_filters = 18