pcdsdevices.digitizers.Wave8V2ADCRegs
- class pcdsdevices.digitizers.Wave8V2ADCRegs(*args, **kwargs)
Class for accessing LCLS-II Wave8 ADC registers.
Attribute
Class
Suffix
Docs
Kind
Notes
adc_reg_x0006
EpicsSignal
:AdcReg_0x0006_RBV
config
adc_reg_x0007
EpicsSignal
:AdcReg_0x0007_RBV
config
adc_reg_x0008
EpicsSignal
:AdcReg_0x0008_RBV
config
adc_reg_x000B
EpicsSignal
:AdcReg_0x000B_RBV
config
adc_reg_x000C
EpicsSignal
:AdcReg_0x000C_RBV
config
adc_reg_x000D
EpicsSignal
:AdcReg_0x000D_RBV
config
adc_reg_x000F
EpicsSignal
:AdcReg_0x000F_RBV
config
adc_reg_x0010
EpicsSignal
:AdcReg_0x0010_RBV
config
adc_reg_x0011
EpicsSignal
:AdcReg_0x0011_RBV
config
adc_reg_x0012
EpicsSignal
:AdcReg_0x0012_RBV
config
adc_reg_x0013
EpicsSignal
:AdcReg_0x0013_RBV
config
adc_reg_x0014
EpicsSignal
:AdcReg_0x0014_RBV
config
adc_reg_x0015
EpicsSignal
:AdcReg_0x0015_RBV
config
adc_reg_x0016
EpicsSignal
:AdcReg_0x0016_RBV
config
adc_reg_x0017
EpicsSignal
:AdcReg_0x0017_RBV
config
adc_reg_x0018
EpicsSignal
:AdcReg_0x0018_RBV
config
adc_reg_x001F
EpicsSignal
:AdcReg_0x001F_RBV
config
adc_reg_x0020
EpicsSignal
:AdcReg_0x0020_RBV
config
Methods
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs
. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read()
.This keys in the
OrderedDict
this method returns must match the keys in theOrderedDict
return byread()
.This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_key
schema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger()
.The
OrderedDict
returned by this method must have identical keys (in the same order) as theOrderedDict
returned bydescribe()
.By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky
.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}
. The'value'
may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrs
list.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()
method) then this method is also responsible for arranging that theStatusBase
object returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBase
object which is already completed.- Returns:
status (StatusBase) –
StatusBase
object which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind