pcdsdevices.digitizers.Wave8V2ADCRegs

class pcdsdevices.digitizers.Wave8V2ADCRegs(*args, **kwargs)

Class for accessing LCLS-II Wave8 ADC registers.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

adc_reg_x0006

EpicsSignal

:AdcReg_0x0006_RBV

config

adc_reg_x0007

EpicsSignal

:AdcReg_0x0007_RBV

config

adc_reg_x0008

EpicsSignal

:AdcReg_0x0008_RBV

config

adc_reg_x000B

EpicsSignal

:AdcReg_0x000B_RBV

config

adc_reg_x000C

EpicsSignal

:AdcReg_0x000C_RBV

config

adc_reg_x000D

EpicsSignal

:AdcReg_0x000D_RBV

config

adc_reg_x000F

EpicsSignal

:AdcReg_0x000F_RBV

config

adc_reg_x0010

EpicsSignal

:AdcReg_0x0010_RBV

config

adc_reg_x0011

EpicsSignal

:AdcReg_0x0011_RBV

config

adc_reg_x0012

EpicsSignal

:AdcReg_0x0012_RBV

config

adc_reg_x0013

EpicsSignal

:AdcReg_0x0013_RBV

config

adc_reg_x0014

EpicsSignal

:AdcReg_0x0014_RBV

config

adc_reg_x0015

EpicsSignal

:AdcReg_0x0015_RBV

config

adc_reg_x0016

EpicsSignal

:AdcReg_0x0016_RBV

config

adc_reg_x0017

EpicsSignal

:AdcReg_0x0017_RBV

config

adc_reg_x0018

EpicsSignal

:AdcReg_0x0018_RBV

config

adc_reg_x001F

EpicsSignal

:AdcReg_0x001F_RBV

config

adc_reg_x0020

EpicsSignal

:AdcReg_0x0020_RBV

config

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

post_elog_status()

Post device status to the primary elog, if possible.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

status() str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})