pcdsdevices.eps.EPS

class pcdsdevices.eps.EPS(*args, **kwargs)

Corresponds to DUT_EPS from lcls-twincat-general.

This struct represents a combined EPS status that can be made up of many independent protection factors. It summarizes all of the EPS information in a way that can be consumed by higher level applications so that the user knows exactly why their motor cannot move, why their valve cannot open, etc.

This has a corresponding EPS widget in pcdswidgets, so this class only makes minimal adjustments to make the default typhos view usable.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

eps_ok

PytmcSignal

bEPS_OK

EPS summary: true if everything is OK

normal

message

PytmcSignal

sMessage

Message from EPS to the user.

normal

flags_raw

PytmcSignal

nFlags

Raw EPS bitmask

omitted

flags

InternalSignal

normal

flag_desc

PytmcSignal

sFlagDesc

Semicolon-delimited descriptions of each flag

omitted

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

post_elog_status()

Post device status to the primary elog, if possible.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

status() str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})