pcdsdevices.lasers.rfof.ItechRfofErrors

class pcdsdevices.lasers.rfof.ItechRfofErrors(*args, **kwargs)

Itech RFOF Error PVs

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

eth_con_err

EpicsSignalRO

:ETH_CON_ERR

Tx/Rx Ethernet connection failure

normal

pwr_supply_v_err

EpicsSignalRO

:PWR_SUPPLY_V_ERR

Power supply voltages are out of range

normal

env_cond_err

EpicsSignalRO

:ENV_COND_ERR

Environmental conditions are out of range

normal

int_mod_err

EpicsSignalRO

:INT_MOD_ERR

Internal modules temperatures are out of range

normal

rf_pwr_err

EpicsSignalRO

:RF_PWR_ERR

RF power is out of range

normal

opt_pwr_err

EpicsSignalRO

:OPT_PWR_ERR

Optical power is too low

normal

las_pwr_err

EpicsSignalRO

:LAS_PWR_ERR

Laser is switched off

normal

phase_err

EpicsSignalRO

:PHASE_ERR

Phase loops are not locked

normal

fan_spd_err

EpicsSignalRO

:FAN_SPD_ERR

Fan revolutions are too low

normal

pwr_supply_i_err

EpicsSignalRO

:PWR_SUPPLY_I_ERR

Power supply currents are too high

normal

tx_eth_err

EpicsSignalRO

:TX_ETH_SYNC_ERR

Tx: Ethernet sync between units lost for more than 10 min

normal

rx_eth_err

EpicsSignalRO

:RX_ETH_SYNC_ERR

Rx: Ethernet sync between units lost for more than 10 min

normal

tx_input_err

EpicsSignalRO

:TX_RF_INPUT_ERR

RF input is out of range for more than 60s

normal

rx_output_err

EpicsSignalRO

:RX_RF_OUTPUT_ERR

RF output is out of range for more than 10 min

normal

tx_temp_sens_err

EpicsSignalRO

:TX_TEMP_SENS_ERR

Tx: Temperature sensors are not working properly; TEC protection activated

normal

rx_temp_sens_err

EpicsSignalRO

:RX_TEMP_SENS_ERR

Rx: Temperature sensors are not working properly; TEC protection activated

normal

tx_rf_idn_err

EpicsSignalRO

:TX_RF_IDN_ERR

Tx: RF control identification failed

normal

tx_rf_sens_err

EpicsSignalRO

:TX_RF_SENS_ERR

Tx: RF control sensor failure

normal

tx_arm_idn_err

EpicsSignalRO

:TX_ARM_IDN_ERR

Tx: Arm control identification failed

normal

tx_arm_sens_err

EpicsSignalRO

:TX_ARM_SENS_ERR

Tx: Arm control sensor failure

normal

unlock_err

EpicsSignalRO

:UNLOCK_ERR

System is unlocked for more than 15 min

normal

rx_rf_idn_err

EpicsSignalRO

:RX_RF_IDN_ERR

Rx: RF control identification failed

normal

rx_rf_sens_err

EpicsSignalRO

:RX_RF_SENS_ERR

Rx: RF control sensor failure

normal

rx_arm_idn_err

EpicsSignalRO

:RX_ARM_IDN_ERR

Rx: Arm control identification failed

normal

rx_arm_sens_err

EpicsSignalRO

:RX_ARM_SENS_ERR

Rx: Arm control sensor failure

normal

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

post_elog_status()

Post device status to the primary elog, if possible.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

status() str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})