pcdsdevices.lodcm.SimEnergyC
- class pcdsdevices.lodcm.SimEnergyC(prefix, *args, **kwargs)
Energy C Simulator for Testing
Attribute
Class
Suffix
Docs
Kind
Notes
tower1 (FCpt)
{self._prefix}
normal
Inherited from
LODCMEnergyC
tower2 (FCpt)
{self._prefix}
normal
Inherited from
LODCMEnergyC
dr
normal
Inherited from
LODCMEnergyC
th1C
normal
Inherited from
LODCMEnergyC
th2C
normal
Inherited from
LODCMEnergyC
z1C
normal
Inherited from
LODCMEnergyC
z2C
normal
Inherited from
LODCMEnergyC
energy
hinted
Inherited from
LODCMEnergyC
Methods
- calc_geometry(energy, material='C', reflection=None)
Calculate the lom geometry.
- camonitor()
Shows a live-updating motor position in the terminal.
This will be the value that is returned by the
position
attribute.This method ends cleanly at a ctrl+c or after a call to
end_monitor_thread()
, which may be useful when this is called in a background thread.
- check_single(pseudo_single, single_pos)
Check if a new position for a single pseudo positioner is valid
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs
. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read()
.This keys in the
OrderedDict
this method returns must match the keys in theOrderedDict
return byread()
.This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_key
schema.
- end_monitor_thread()
Stop a
camonitor()
orwm_update()
that is running in another thread.
- forward(pseudo_pos)
Calculate a RealPosition from a given PseudoPosition.
If the pseudo positioner is here at
pseudo_pos
, then this is where my real motor should be.- Parameters:
pseudo_pos (PseudoPosition) – The pseudo position input, a namedtuple.
- Returns:
real_pos (RealPosition) – The real position output, a namedtuple.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- get_energy(material='C', reflection=None)
Get photon energy from first tower in keV.
Energy is determined by the first crystal (Theta motor).
- get_reflection()
Get the crystal reflection.
Check both towers, and compare the if they match. If they do not match an error will be raised.
- Returns:
ref_1 (tuple) – Reflection of the two Crystal Towers.
- Raises:
ValueError – When the reflection of first tower does not match the one of second tower.
- inverse(real_pos)
Calculate a PseudoPosition from a given RealPosition.
If the real motor is at this
real_pos
, then this is where my pseudo position should be.- Parameters:
real_pos (RealPosition) – The real position input.
- Returns:
pseudo_pos (PseudoPosition) – The pseudo position output.
- move(*args, **kwargs)
Move to a specified position, optionally waiting for motion to complete.
- Parameters:
position – Pseudo position to move to.
moved_cb (callable) – Call this callback when movement has finished. This callback must accept one keyword argument: ‘obj’ which will be set to this positioner instance.
timeout (float, optional) – Maximum time to wait for the motion. If None, the default timeout for this positioner is used.
- Returns:
status (MoveStatus)
- Raises:
TimeoutError – When motion takes longer than
timeout
.ValueError – On invalid positions.
RuntimeError – If motion fails other than timing out.
- move_single(pseudo, position, **kwargs)
Move one PseudoSingle axis to a position
All other positioners will use their current setpoint/target value, if available. Failing that, their current readback value will be used (see
PseudoSingle.sync
andPseudoSingle.target
).
- mv(position, timeout=None, wait=False, log=True)
Absolute move to a position.
- Parameters:
position – Desired end position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
wait (bool, optional) – If
True
, wait for motion completion before returning. Defaults toFalse
.log (bool, optional) – If
True
, logs the move at INFO level.
- mv_ginput(timeout=None)
Moves to a location the user clicks on.
If there are existing plots, this will be the position on the most recently active plot. If there are no existing plots, an empty plot will be created with the motor’s limits as the range.
- mvr(delta, timeout=None, wait=False, log=True)
Relative move from this position.
- Parameters:
delta (float) – Desired change in position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
wait (bool, optional) – If
True
, wait for motion completion before returning. Defaults toFalse
.log (bool, optional) – If
True
, logs the move at INFO level.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger()
.The
OrderedDict
returned by this method must have identical keys (in the same order) as theOrderedDict
returned bydescribe()
.By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky
.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}
. The'value'
may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrs
list.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- set(position, **kwargs)
Move to a new position asynchronously
- Parameters:
position (PseudoPosition) – Position for the all of the pseudo axes
- Returns:
status (MoveStatus)
- setE(energy)
- set_current_position(position)
Adjust all offsets so that the pseudo position matches the input.
This will raise an AttributeError if any of the real motors is missing a
set_current_position
method.- Parameters:
position (PseudoPos) – The position
- set_position(position)
Alias for set_current_position.
Will fail if the motor does not have set_current_position.
- stage_group_instances() Iterator[OphydObject]
Yields an iterator of subdevices that should be staged.
- stop(success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- to_pseudo_tuple(*args, **kwargs)
Convert arguments to a PseudoPosition namedtuple and kwargs
- to_real_tuple(*args, **kwargs)
Convert arguments to a RealPosition namedtuple and kwargs
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()
method) then this method is also responsible for arranging that theStatusBase
object returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBase
object which is already completed.- Returns:
status (StatusBase) –
StatusBase
object which will be marked as complete when the device is ready to be read.
- tweak(scale=0.1)
Control this motor using the arrow keys.
Use left arrow to step negative and right arrow to step positive. Use up arrow to increase step size and down arrow to decrease step size. Press q or ctrl+c to quit.
- Parameters:
scale (float) – starting step size, default = 0.1
- umv(position, timeout=None, log=True, newline=True)
Move to a position, wait, and update with a progress bar.
- Parameters:
position (float) – Desired end position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
log (bool, optional) – If True, logs the move at INFO level.
newline (bool, optional) – If True, inserts a newline after the updates.
- umvr(delta, timeout=None, log=True, newline=True)
Relative move from this position, wait, and update with a progress bar.
- Parameters:
delta (float) – Desired change in position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
log (bool, optional) – If True, logs the move at INFO level.
newline (bool, optional) – If True, inserts a newline after the updates.
- wait(timeout=None)
- wm()
Get the mover’s current positon (where motor).
- wm_update()
Shows a live-updating motor position in the terminal.
This will be the value that is returned by the
position
attribute.This method ends cleanly at a ctrl+c or after a call to
end_monitor_thread()
, which may be useful when this is called in a background thread.
Attributes
- composite_egu
The composite engineering units (EGU) from all PseudoSingles
- concurrent
If concurrent is set, motors will move concurrently (in parallel)
- configuration_attrs
- connected
- egu
The engineering units (EGU) for positions
- high_limit
All PseudoSingle high limits as a namedtuple
- hints
- kind
- limits
All PseudoSingle limits as a namedtuple
- low_limit
All PseudoSingle low limits as a namedtuple
- moving
- needs_parent: list[type[OphydObject]] = [<class 'ophyd.signal.AttributeSignal'>, <class 'ophyd.signal.DerivedSignal'>, <class 'ophyd.areadetector.plugins.PluginBase'>, <class 'ophyd.pseudopos.PseudoSingle'>, <class 'pcdsdevices.signal.PVStateSignal'>, <class 'pcdsdevices.signal.AggregateSignal'>]
- position
Pseudo motor position namedtuple
- pseudo_positioners
Pseudo positioners instances in a namedtuple
- Returns:
positioner_instances (PseudoPosition)
- real_position
Real motor position namedtuple
- real_positioners
Real positioners instances in a namedtuple
- Returns:
positioner_instances (RealPosition)
- sequential
If sequential is set, motors will move in the sequence they were defined in (i.e., in series)
- settle_time
Amount of time to wait after moves to report status completion
- stage_group: list[Component] = [FormattedComponent(IMS, '{self._hutch_prefix}:MON:MMS:19', kind='normal'), FormattedComponent(OffsetMotor, prefix='{self._prefix}:TH1:OFF_C', name='th1_c', motor_prefix='{self._hutch_prefix}:MON:MMS:07', kind='normal'), FormattedComponent(OffsetMotor, prefix='{self._prefix}:TH2:OFF_C', name='th2_c', motor_prefix='{self._hutch_prefix}:MON:MMS:13', kind='normal'), FormattedComponent(OffsetMotor, prefix='{self._prefix}:Z1:OFF_C', name='z1_c', motor_prefix='{self._hutch_prefix}:MON:MMS:04', kind='normal'), FormattedComponent(OffsetMotor, prefix='{self._prefix}:Z2:OFF_C', name='z1_c', motor_prefix='{self._hutch_prefix}:MON:MMS:10', kind='normal')]
- subscriptions: ClassVar[FrozenSet[str]] = frozenset({'_req_done', 'acq_done', 'done_moving', 'readback', 'start_moving'})
- target
Last commanded target positions
- timeout
Amount of time to wait before to considering a motion as failed