class pcdsdevices.mpod_apalis.MPODApalisModule24Channel(*args, **kwargs)

MPODApalis 24 channel Module Object.

Parameters:
  • card_prefix (str) – The EPICS base of the MPOD Module, e.g. ‘TMO:MPOD:01:M6’.

  • name (str) – A name to refer to the device.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

voltage_ramp_speed

EpicsSignal

:VoltageRampSpeed

MPOD module Voltage Ramp Rate [%/sec*Vnom]

normal

Inherited from MPODApalisModule

current_ramp_speed

EpicsSignal

:CurrentRampSpeed

MPOD module current Ramp Rate [%/sec*Inom]

normal

Inherited from MPODApalisModule

temperature

EpicsSignalRO

:Temperature

MPOD Temperature [C]

normal

Inherited from MPODApalisModule

supply_status

EpicsSignalRO

:isSupplyGood

Supply voltages are within range

normal

Inherited from MPODApalisModule

module_status

EpicsSignalRO

:isModuleGood

Module health status

normal

Inherited from MPODApalisModule

fine_adjustment_status

EpicsSignalRO

:isFineAdjustment

Fine adjustment mode status

normal

Inherited from MPODApalisModule

input_status

EpicsSignalRO

:isInputError

Input error in connection with a module access

normal

Inherited from MPODApalisModule

live_insertion_status

EpicsSignalRO

:isLiveInsertion

Live insertion mode status

normal

Inherited from MPODApalisModule

saftey_loop_status

EpicsSignalRO

:isSafetyLoopGood

Saftey loop status

normal

Inherited from MPODApalisModule

kill

EpicsSignal

:isKillEnable

Module-wide kill functionality

normal

Inherited from MPODApalisModule

faults

EpicsSignal

:isEventActive

Clears all MPOD module faults

normal

Inherited from MPODApalisModule

c0

MPODApalisChannel

:C0

normal

c1

MPODApalisChannel

:C1

normal

c2

MPODApalisChannel

:C2

normal

c3

MPODApalisChannel

:C3

normal

c4

MPODApalisChannel

:C4

normal

c5

MPODApalisChannel

:C5

normal

c6

MPODApalisChannel

:C6

normal

c7

MPODApalisChannel

:C7

normal

c8

MPODApalisChannel

:C8

normal

c9

MPODApalisChannel

:C9

normal

c10

MPODApalisChannel

:C10

normal

c11

MPODApalisChannel

:C11

normal

c12

MPODApalisChannel

:C12

normal

c13

MPODApalisChannel

:C13

normal

c14

MPODApalisChannel

:C14

normal

c15

MPODApalisChannel

:C15

normal

c16

MPODApalisChannel

:C16

normal

c17

MPODApalisChannel

:C17

normal

c18

MPODApalisChannel

:C18

normal

c19

MPODApalisChannel

:C19

normal

c20

MPODApalisChannel

:C20

normal

c21

MPODApalisChannel

:C21

normal

c22

MPODApalisChannel

:C22

normal

c23

MPODApalisChannel

:C23

normal

Methods

clear_faults()

Clears all module faults

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

post_elog_status()

Post device status to the primary elog, if possible.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

set_current_ramp_speed(ramp_speed)

Set the current ramp speed in %/sec*Inom.

It sets the current ramp speed for the entire card.

Parameters:

ramp_speed (number) – Current ramp speed [%/sec*Vnom].

set_voltage_ramp_speed(ramp_speed)

Set the voltage ramp speed in %/sec*Vnom.

It sets the voltage ramp speed for the entire card.

Parameters:

ramp_speed (number) – Voltage rise rate [%/sec*Vnom].

stage_group_instances() Iterator[OphydObject]

Yields an iterator of subdevices that should be staged.

status() str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
needs_parent: list[type[OphydObject]] = [<class 'ophyd.signal.AttributeSignal'>, <class 'ophyd.signal.DerivedSignal'>, <class 'ophyd.areadetector.plugins.PluginBase'>, <class 'ophyd.pseudopos.PseudoSingle'>, <class 'pcdsdevices.signal.PVStateSignal'>, <class 'pcdsdevices.signal.AggregateSignal'>]
stage_group: list[Component] = None
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})