pcdsdevices.pim.PPMPowerMeter

class pcdsdevices.pim.PPMPowerMeter(*args, **kwargs)

Analog measurement tool for beam energy as part of the PPM assembly.

When inserted into the beam, the raw_voltage signal value should increase proportional to the beam energy. The equivalent calibrated readings are dimensionless, which is a unitless number that represents the relative calibration of every power meter, and calibrated_mj, which is the real engineering unit of the beam power. These are calibrated using the other signals in the following way:

dimensionless = (raw_voltage + calib_offset) * calib_ratio calibrated_mj = dimensionless * calib_mj_ratio

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

raw_voltage

PytmcSignal

:VOLT

Raw readback from the power meter.

normal

dimensionless

PytmcSignal

:CALIB

Calibrated dimensionless readback for cross-meter comparisons.

normal

calibrated_mj

PytmcSignal

:MJ

Calibrated absolute measurement of beam power in physics units.

normal

thermocouple

TwinCATThermocouple

Thermocouple on the power meter holder.

normal

calib_offset

PytmcSignal

:CALIB:OFFSET

Calibration parameter to offset raw voltage to zero for the calibrated quantities. Unique per power meter.

config

calib_ratio

PytmcSignal

:CALIB:RATIO

Calibration multiplier to convert to the dimensionless constant. Unique per power meter.

config

calib_mj_ratio

PytmcSignal

:CALIB:MJ_RATIO

Calibration multiplier to convert from the dimensionless constant to calibrated scientific quantity. Same for every power meter.

config

raw_voltage_buffer

PytmcSignal

:VOLT_BUFFER

Array of the last 1000 raw measurements. Polls faster than the EPICS updates.

omitted

dimensionless_buffer

PytmcSignal

:CALIB_BUFFER

Array of the last 1000 dimensionless measurements. Polls faster than the EPICS updates.

omitted

calibrated_mj_buffer

PytmcSignal

:MJ_BUFFER

Array of the last 1000 fully calibrated measurements. Polls faster than the EPICS updates.

omitted

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

post_elog_status()

Post device status to the primary elog, if possible.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

status() str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})