pcdsdevices.pump.Navigator

class pcdsdevices.pump.Navigator(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)

Class for Navigator Pump controlled via serial.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

run

EpicsSignal

:RUN

omitted

Inherited from AgilentSerial

config

EpicsSignal

:CONFIG

omitted

Inherited from AgilentSerial

softstart

EpicsSignal

:SOFTSTART

omitted

Inherited from AgilentSerial

sp_type

EpicsSignal

:SP_TYPE

omitted

Inherited from AgilentSerial

sp_calcdis

EpicsSignal

:SP_CALCDIS

omitted

Inherited from AgilentSerial

sp_dis

EpicsSignal

:SP_DIS

omitted

Inherited from AgilentSerial

sp_writeval

EpicsSignal

:SP_WRITEVAL

omitted

Inherited from AgilentSerial

sp_freq

EpicsSignal

:SP_FREQ

omitted

Inherited from AgilentSerial

sp_current

EpicsSignal

:SP_CURRENT

omitted

Inherited from AgilentSerial

sp_time

EpicsSignalRO

:SP_TIME_RBV

omitted

Inherited from AgilentSerial

sp_delay

EpicsSignal

:SP_DELAY

omitted

Inherited from AgilentSerial

sp_polarity

EpicsSignal

:SP_POLARITY

omitted

Inherited from AgilentSerial

sp_hys

EpicsSignal

:SP_HYS

omitted

Inherited from AgilentSerial

water_cooling

EpicsSignal

:WATER_COOLING

normal

Inherited from AgilentSerial

active_stop

EpicsSignal

:ACTIVE_STOP

normal

Inherited from AgilentSerial

interlock_type

EpicsSignal

:INTERLOCK_TYPE

omitted

Inherited from AgilentSerial

ao_type

EpicsSignal

:AO_TYPE

omitted

Inherited from AgilentSerial

rot_freq

EpicsSignal

:ROT_FREQ

normal

Inherited from AgilentSerial

vent_valve

EpicsSignal

:VENT_VALVE

omitted

Inherited from AgilentSerial

vent_valve_operation

EpicsSignal

:VENT_VALVE_OPERATION

omitted

Inherited from AgilentSerial

vent_valve_delay

EpicsSignal

:VENT_VALVE_DELAY

omitted

Inherited from AgilentSerial

vent_valve_raw

EpicsSignal

:VENT_VALVE_RAW

omitted

Inherited from AgilentSerial

pump_current

EpicsSignalRO

:PUMP_CURRENT_RBV

omitted

Inherited from AgilentSerial

pump_voltage

EpicsSignalRO

:PUMP_VOLTAGE_RBV

normal

Inherited from AgilentSerial

pump_power

EpicsSignalRO

:PUMP_POWER_RBV

normal

Inherited from AgilentSerial

pump_drive_freq

EpicsSignalRO

:PUMP_DRIVE_FREQ_RBV

normal

Inherited from AgilentSerial

pump_temp

EpicsSignalRO

:PUMP_TEMP_RBV

normal

Inherited from AgilentSerial

pump_status

EpicsSignalRO

:PUMP_STATUS_RBV

normal

Inherited from AgilentSerial

pump_error

EpicsSignalRO

:PUMP_ERROR_RBV

normal

Inherited from AgilentSerial

low_speed

EpicsSignalRO

:LOW_SPEED_RBV

omitted

low_speed_freq

EpicsSignalRO

:LOW_SPEED_FREQ_RBV

omitted

sp_power

EpicsSignalRO

:SP_POWER_RBV

omitted

sp_normal

EpicsSignalRO

:SP_NORMAL_RBV

omitted

sp_pressure

EpicsSignalRO

:SP_PRESSURE_RBV

omitted

vent_open_time

EpicsSignalRO

:VENT_OPEN_TIME_RBV

omitted

vent_open_time_raw

EpicsSignalRO

:VENT_OPEN_TIME_RAW_RBV

omitted

power_limit

EpicsSignalRO

:POWER_LIMIT_RBV

omitted

gas_load_type

EpicsSignalRO

:GAS_LOAD_TYPE_RBV

omitted

press_read_corr

EpicsSignalRO

:PRESS_READ_CORR_RBV

omitted

sp_press_unit

EpicsSignalRO

:SP_PRESS_UNIT_RBV

omitted

sp_write_press_unit

EpicsSignalRO

:SP_WRITE_PRESS_UNIT_RBV

omitted

stop_speed_reading

EpicsSignalRO

:STOP_SPEED_READING_RBV

omitted

ctrl_heatsink_temp

EpicsSignalRO

:CTRL_HEATSINK_TEMP_RBV

omitted

ctrl_air_temp

EpicsSignalRO

:CTRL_AIR_TEMP_RBV

omitted

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})