pcdsdevices.epics_motor.BeckhoffAxisEPS
- class pcdsdevices.epics_motor.BeckhoffAxisEPS(*args, **kwargs)
A beckhoff axis where the EPS indicators are relevant.
This is to be used for cases when the motor has EPS considerations. Otherwise, these fields are not active in PLC logic and are distracting or confusing.
Attribute
Class
Suffix
Docs
Kind
Notes
user_readback (UpdateComponent)
.RBV
- Component attribute
Component(EpicsSignalRO, '.RBV', auto_monitor=True, kind='hinted')
hinted
Inherited from
BeckhoffAxis
user_setpoint (UpdateComponent)
.VAL
- Component attribute
Component(EpicsSignal, '.VAL', limits=True, auto_monitor=True, kind='normal')
normal
Inherited from
BeckhoffAxis
user_offset
EpicsSignal
.OFF
config
Inherited from
BeckhoffAxis
user_offset_dir
EpicsSignal
.DIR
config
Inherited from
BeckhoffAxis
offset_freeze_switch
EpicsSignal
.FOFF
omitted
Inherited from
BeckhoffAxis
set_use_switch
EpicsSignal
.SET
omitted
Inherited from
BeckhoffAxis
velocity
EpicsSignal
.VELO
config
Inherited from
BeckhoffAxis
acceleration
EpicsSignal
.ACCL
config
Inherited from
BeckhoffAxis
motor_egu
EpicsSignal
.EGU
config
Inherited from
BeckhoffAxis
motor_is_moving
EpicsSignalRO
.MOVN
normal
Inherited from
BeckhoffAxis
motor_done_move
EpicsSignalRO
.DMOV
omitted
Inherited from
BeckhoffAxis
high_limit_switch
EpicsSignalRO
.HLS
normal
Inherited from
BeckhoffAxis
low_limit_switch
EpicsSignalRO
.LLS
normal
Inherited from
BeckhoffAxis
high_limit_travel (UpdateComponent)
EpicsSignal
.HLM
- Component attribute
Component(EpicsSignal, '.HLM', auto_monitor=True, kind='omitted')
config
Inherited from
BeckhoffAxis
low_limit_travel (UpdateComponent)
EpicsSignal
.LLM
- Component attribute
Component(EpicsSignal, '.LLM', auto_monitor=True, kind='omitted')
config
Inherited from
BeckhoffAxis
direction_of_travel
EpicsSignal
.TDIR
normal
Inherited from
BeckhoffAxis
motor_stop
EpicsSignal
.STOP
normal
Inherited from
BeckhoffAxis
disabled
EpicsSignal
.DISP
omitted
Inherited from
BeckhoffAxis
description
EpicsSignal
.DESC
normal
Inherited from
BeckhoffAxis
dial_position
EpicsSignalRO
.DRBV
normal
Inherited from
BeckhoffAxis
velocity_base
EpicsSignal
.VBAS
omitted
Inherited from
BeckhoffAxis
velocity_max
EpicsSignal
.VMAX
config
Inherited from
BeckhoffAxis
msta_raw
EpicsSignalRO
.MSTA
omitted
Inherited from
BeckhoffAxis
plc
:PLC:
PLC error handling, aux functions, and EPS.
normal
Inherited from
BeckhoffAxis
motor_spmg
EpicsSignal
.SPMG
Stop, Pause, Move, Go
config
Inherited from
BeckhoffAxis
Methods
- camonitor()
Shows a live-updating motor position in the terminal.
This will be the value that is returned by the
position
attribute.This method ends cleanly at a ctrl+c or after a call to
end_monitor_thread()
, which may be useful when this is called in a background thread.
- check_limit_switches()
Check the limits switches.
- Returns:
limit_switch_indicator (str) – Indicate which limit switch is activated.
- clear_error()
Clear any active motion errors on this axis.
- clear_limits()
Set both low and high limits to 0.
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs
. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read()
.This keys in the
OrderedDict
this method returns must match the keys in theOrderedDict
return byread()
.This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_key
schema.
- disable()
Disables the motor.
When disabled, all EPICS puts to the base record will be dropped.
- enable()
Enables the motor.
When disabled, all EPICS puts to the base record will be dropped.
- end_monitor_thread()
Stop a
camonitor()
orwm_update()
that is running in another thread.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- get_high_limit()
Get high limit.
- get_lim(flag)
Returns the travel limit of motor
flag > 0: returns high limit
flag < 0: returns low limit
flag == 0: returns None
Included here for compatibility with similar with SPEC command.
- get_low_limit()
Get the low limit.
- home(direction=None, wait=True, **kwargs)
Perform the configured homing function.
This is set on the controller. Unlike other kinds of axes, only the single pre-programmed homing routine can be used, so the
direction
argument has no effect.
- move(position: float, wait: bool = True, **kwargs) MoveStatus
Move to a specified position, optionally waiting for motion to complete.
- Parameters:
position – Position to move to
moved_cb (callable) – Call this callback when movement has finished. This callback must accept one keyword argument: ‘obj’ which will be set to this positioner instance.
timeout (float, optional) – Maximum time to wait for the motion. If None, the default timeout for this positioner is used.
- Returns:
status (MoveStatus)
- Raises:
TimeoutError – When motion takes longer than
timeout
ValueError – On invalid positions
RuntimeError – If motion fails other than timing out
- mv(position, timeout=None, wait=False, log=True)
Absolute move to a position.
- Parameters:
position – Desired end position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
wait (bool, optional) – If
True
, wait for motion completion before returning. Defaults toFalse
.log (bool, optional) – If
True
, logs the move at INFO level.
- mv_ginput(timeout=None)
Moves to a location the user clicks on.
If there are existing plots, this will be the position on the most recently active plot. If there are no existing plots, an empty plot will be created with the motor’s limits as the range.
- mvr(delta, timeout=None, wait=False, log=True)
Relative move from this position.
- Parameters:
delta (float) – Desired change in position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
wait (bool, optional) – If
True
, wait for motion completion before returning. Defaults toFalse
.log (bool, optional) – If
True
, logs the move at INFO level.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger()
.The
OrderedDict
returned by this method must have identical keys (in the same order) as theOrderedDict
returned bydescribe()
.By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky
.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}
. The'value'
may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrs
list.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- set(new_position: Any, *, timeout: float | None = None, moved_cb: Callable | None = None, wait: bool = False) StatusBase
Set a value and return a Status object
- Parameters:
new_position (object) – The input here is whatever the device requires (this should be over-ridden by the implementation. For example a motor would take a float, a shutter the strings {‘Open’, ‘Close’}, and a goineometer (h, k, l) tuples
timeout (float, optional) – Maximum time to wait for the motion. If None, the default timeout for this positioner is used.
moved_cb (callable, optional) –
Deprecated
Call this callback when movement has finished. This callback must accept one keyword argument: ‘obj’ which will be set to this positioner instance.
wait (bool, optional) –
Deprecated
If the method should block until the Status object reports it is done.
Defaults to False
- Returns:
status (StatusBase) – Status object to indicate when the motion / set is done.
- set_current_position(pos)
Configure the motor user position to the given value
Override ophyd’s method temporarily for error handling.
- Parameters:
pos (number) – Position to set.
- set_high_limit(value)
Limit of travel in the positive direction.
- Parameters:
value (float) – High limit value to be set.
- Raises:
ValueError – When motor in motion or position outside of limit.
- set_lim(low, high)
Sets the low and high travel limits of motor
No action taken if motor is moving.
Low limit is set to lesser of (low, high)
High limit is set to greater of (low, high)
Included here for compatibility with similar with SPEC command.
- set_low_limit(value)
Set the low limit.
- Parameters:
value (float) – Limit of travel in the negative direction.
- Raises:
ValueError – When motor in motion or position outside of limit.
- set_position(position)
Alias for set_current_position.
Will fail if the motor does not have set_current_position.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()
method) then this method is also responsible for arranging that theStatusBase
object returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBase
object which is already completed.- Returns:
status (StatusBase) –
StatusBase
object which will be marked as complete when the device is ready to be read.
- tweak(scale=0.1)
Control this motor using the arrow keys.
Use left arrow to step negative and right arrow to step positive. Use up arrow to increase step size and down arrow to decrease step size. Press q or ctrl+c to quit.
- Parameters:
scale (float) – starting step size, default = 0.1
- umv(position, timeout=None, log=True, newline=True)
Move to a position, wait, and update with a progress bar.
- Parameters:
position (float) – Desired end position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
log (bool, optional) – If True, logs the move at INFO level.
newline (bool, optional) – If True, inserts a newline after the updates.
- umvr(delta, timeout=None, log=True, newline=True)
Relative move from this position, wait, and update with a progress bar.
- Parameters:
delta (float) – Desired change in position.
timeout (float, optional) – If provided, the mover will throw an error if motion takes longer than timeout to complete. If omitted, the mover’s default timeout will be use.
log (bool, optional) – If True, logs the move at INFO level.
newline (bool, optional) – If True, inserts a newline after the updates.
- wait(timeout=None)
- wm()
Get the mover’s current positon (where motor).
- wm_update()
Shows a live-updating motor position in the terminal.
This will be the value that is returned by the
position
attribute.This method ends cleanly at a ctrl+c or after a call to
end_monitor_thread()
, which may be useful when this is called in a background thread.
Attributes
- configuration_attrs
- connected
- egu
Engineering units str if available, otherwise ‘’
Use the monitored/cached value rather than checking EPICS.
- high_limit
- hints
- home_forward = None
- home_reverse = None
- homed
Get the home status of the motor as reported by the MSTA field.
- kind
- limits
Override the limits attribute
- low_limit
- moving
Whether or not the motor is moving
- Returns:
moving (bool)
- msta
Returns the msta fields as a dictionary.
- position
The current position of the motor in its engineering units
- Returns:
position (float)
- precision
The precision of the readback PV, as reported by EPICS
- settle_time
Amount of time to wait after moves to report status completion
- subscriptions: ClassVar[FrozenSet[str]] = frozenset({'_req_done', 'acq_done', 'done_moving', 'readback', 'start_moving'})
- timeout
Amount of time to wait before to considering a motion as failed
- tolerated_alarm = 0