pcdsdevices.gauge.GCCPLC

class pcdsdevices.gauge.GCCPLC(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)

Class for a Cold Cathode Gauge controlled by PLC.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

pressure

EpicsSignalRO

:PRESS_RBV

gauge pressure reading

hinted

Inherited from GaugePLC

gauge_at_vac

EpicsSignalRO

:AT_VAC_RBV

gauge is at VAC

normal

Inherited from GaugePLC

pressure_ok

EpicsSignalRO

:PRESS_OK_RBV

pressure reading ok

normal

Inherited from GaugePLC

at_vac_setpoint

EpicsSignalWithRBV

:VAC_SP

At vacuum setpoint for all gauges

config

Inherited from GaugePLC

state

EpicsSignalRO

:STATE_RBV

state of the gauge

hinted

Inherited from GaugePLC

high_voltage_on

EpicsSignalWithRBV

:HV_SW

command to switch the high voltage on

normal

high_voltage_disable

EpicsSignalRO

:HV_DIS_DO_RBV

enables the high voltage on the cold cathode gauge

normal

protection_setpoint

EpicsSignalWithRBV

:PRO_SP

Protection setpoint for ion gauges at which the gauge turns off

normal

setpoint_hysterisis

EpicsSignalWithRBV

:SP_HYS

Protection setpoint hysteresis

config

interlock_ok

EpicsSignalRO

:ILK_OK_RBV

Interlock is ok

normal

auto_on

EpicsSignalWithRBV

:Auto_On

Setting to automatically turn on the gauge when thereference gauge pressure is below protection setpoint

config

autoOn_countdown

EpicsSignalRO

:AutoOn_timer_RBV

timer count down to turn on the gauge

normal

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind