pcdsdevices.gauge.GFSPLC
- class pcdsdevices.gauge.GFSPLC(prefix='', *, name, kind=None, read_attrs=None, configuration_attrs=None, parent=None, **kwargs)
Class for a fast shutter sensor gauge controlled by PLC.
Attribute
Class
Suffix
Docs
Kind
Notes
pressure
EpicsSignalRO
:PRESS_RBV
gauge pressure reading
hinted
Inherited from
GCCPLC
gauge_at_vac
EpicsSignalRO
:AT_VAC_RBV
gauge is at VAC
normal
Inherited from
GCCPLC
pressure_ok
EpicsSignalRO
:PRESS_OK_RBV
pressure reading ok
normal
Inherited from
GCCPLC
at_vac_setpoint
:VAC_SP
At vacuum setpoint for all gauges
config
Inherited from
GCCPLC
state
EpicsSignalRO
:STATE_RBV
state of the gauge
hinted
Inherited from
GCCPLC
high_voltage_on
:HV_SW
command to switch the high voltage on
normal
Inherited from
GCCPLC
high_voltage_disable
EpicsSignalRO
:HV_DIS_DO_RBV
enables the high voltage on the cold cathode gauge
normal
Inherited from
GCCPLC
protection_setpoint
:PRO_SP
Protection setpoint for ion gauges at which the gauge turns off
normal
Inherited from
GCCPLC
setpoint_hysterisis
:SP_HYS
Protection setpoint hysteresis
config
Inherited from
GCCPLC
interlock_ok
EpicsSignalRO
:ILK_OK_RBV
Interlock is ok
normal
Inherited from
GCCPLC
auto_on
:Auto_On
Setting to automatically turn on the gauge when thereference gauge pressure is below protection setpoint
config
Inherited from
GCCPLC
autoOn_countdown
EpicsSignalRO
:AutoOn_timer_RBV
timer count down to turn on the gauge
normal
Inherited from
GCCPLC
fault_setpoint_FS
EpicsSignalRO
:PSTATSPRBCK_FS
Vacuum fault setpoint for Fast shutter valve
config
Methods
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs
. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read()
.This keys in the
OrderedDict
this method returns must match the keys in theOrderedDict
return byread()
.This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_key
schema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger()
.The
OrderedDict
returned by this method must have identical keys (in the same order) as theOrderedDict
returned bydescribe()
.By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky
.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}
. The'value'
may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrs
list.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()
method) then this method is also responsible for arranging that theStatusBase
object returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBase
object which is already completed.- Returns:
status (StatusBase) –
StatusBase
object which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind