pcdsdevices.pneumatic.BeckhoffPneumatic

class pcdsdevices.pneumatic.BeckhoffPneumatic(*args, **kwargs)

Class containing basic Beckhoff Pneumatic support

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

lightpath_summary

SummarySignal

omitted

Inherited from LightpathMixin

limit_switch_in

PytmcSignal

:PLC:bInLimitSwitch

normal

limit_switch_out

PytmcSignal

:PLC:bOutLimitSwitch

normal

retract_status

PytmcSignal

:bRetractDigitalOutput

normal

insert_status

PytmcSignal

:bInsertDigitalOutput

normal

interlock_ok

PytmcSignal

:bInterlockOK

normal

insert_ok

PytmcSignal

:bInsertEnable

normal

retract_ok

PytmcSignal

:bRetractEnable

normal

insert_signal

PytmcSignal

:CMD:IN

normal

retract_signal

PytmcSignal

:CMD:OUT

normal

busy

PytmcSignal

:bBusy

normal

done

PytmcSignal

:bDone

normal

reset

PytmcSignal

:bReset

normal

error

PytmcSignal

:PLC:bError

normal

error_id

PytmcSignal

:PLC:nErrorId

normal

error_message

PytmcSignal

:PLC:sErrorMessage

normal

position_state

PytmcSignal

:nPositionState

hinted

Methods

calc_lightpath_state(limit_switch_in=None, limit_switch_out=None)

Create and return a LightpathState object containing information needed for lightpath, given a set of signal values

kwargs should be the same as the signal names provided in lightpath_cpts

Device logic goes here.

Returns:

LightpathState – a dataclass containing the Lightpath state

callback(*, old_value, value, **kwargs)
configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

get_lightpath_state(use_cache: bool = True) LightpathState

Return the current LightpathState

Returns:

LightpathState – a dataclass containing the Lightpath state

insert(wait: bool = False, timeout: float = 10.0) Status

Method for inserting Beckhoff Pneumatic Actuator

post_elog_status()

Post device status to the primary elog, if possible.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

remove(wait: bool = False, timeout: float = 10.0) Status

Method for removing Beckhoff Pneumatic Actuator

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

status() str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
lightpath_cpts = ['limit_switch_in', 'limit_switch_out']
md
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})