pcdsdevices.valve.VRC

class pcdsdevices.valve.VRC(*args, input_branches=[], output_branches=[], **kwargs)

VRC = Valve with Readback and Control

This is the standard normally-closed valve class. It corresponds with ST_VRC in the lcls-twincat-vacuum library, though it also adds some PVs from ST_ValveBase.

This class does not contain detailed interlocking information, rather it only includes whether or not an interlock is present.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

lightpath_summary

SummarySignal

omitted

Inherited from LightpathMixin

valve_position

EpicsSignalRO

:POS_STATE_RBV

Ex: OPEN, CLOSED, MOVING, INVALID, OPEN_F

hinted

Inherited from VVC

open_command

EpicsSignalWithRBV

:OPN_SW

Epics command to Open valve

normal

Inherited from VVC

interlock_ok

EpicsSignalRO

:OPN_OK_RBV

Valve is OK to Open interlock

normal

Inherited from VVC

open_do

EpicsSignalRO

:OPN_DO_RBV

PLC Output to Open valve, 1 means 24V on command cable

normal

Inherited from VVC

error_reset

EpicsSignalWithRBV

:ALM_RST

Reset Error state to valid by toggling this

normal

Inherited from VVC

override_status

EpicsSignalRO

:OVRD_ON_RBV

Epics Readback on Override mode

omitted

Inherited from VVC

override_force_open

EpicsSignalWithRBV

:FORCE_OPN

Epics Command to force open the valve inoverride mode

omitted

Inherited from VVC

state

EpicsSignalRO

:STATE_RBV

Valve state

normal

open_limit

EpicsSignalRO

:OPN_DI_RBV

Open limit switch digital input

hinted

closed_limit

EpicsSignalRO

:CLS_DI_RBV

Closed limit switch digital input

hinted

Methods

calc_lightpath_state(open_limit: int, closed_limit: int) LightpathState

Callback for updating inserted/removed for lightpath.

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

get_lightpath_state(use_cache: bool = True) LightpathState

Return the current LightpathState

Returns:

LightpathState – a dataclass containing the Lightpath state

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
lightpath_cpts = ['open_limit', 'closed_limit']
md
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})