pcdsdevices.qadc.Qadc

class pcdsdevices.qadc.Qadc(*args, **kwargs)

Class for an older Abaco FMC PCIe digitzer, used in the LCLS-I hutches.

Ophyd Device Components

Attribute

Class

Suffix

Docs

Kind

Notes

ch0

EpicsSignal

:CH0

Input 0 of the ADC

normal

Inherited from QadcCommon

ch1

EpicsSignal

:CH1

Input 1 of the ADC

normal

Inherited from QadcCommon

ch2

EpicsSignal

:CH2

Input 2 of the ADC

normal

Inherited from QadcCommon

ch3

EpicsSignal

:CH3

Input 3 of the ADC

normal

Inherited from QadcCommon

config

EpicsSignal

:CONFIG

Write the current config to the QADC

config

Inherited from QadcCommon

start

EpicsSignal

:START

Start/stop acquisition

normal

Inherited from QadcCommon

gain0_i

EpicsSignal

:GAIN0_I

config

gain0_ni

EpicsSignal

:GAIN0_NI

config

gain1_i

EpicsSignal

:GAIN1_I

config

gain1_ni

EpicsSignal

:GAIN1_NI

config

gain2_i

EpicsSignal

:GAIN2_I

config

gain2_ni

EpicsSignal

:GAIN2_NI

config

gain3_i

EpicsSignal

:GAIN3_I

config

gain3_ni

EpicsSignal

:GAIN3_NI

config

ichan

EpicsSignal

:ICHAN

config

interleave

EpicsSignal

:INTERLEAVE

config

length

EpicsSignal

:LENGTH

config

off0_i

EpicsSignal

:OFF0_I

config

off0_ni

EpicsSignal

:OFF0_NI

config

off1_i

EpicsSignal

:OFF1_I

config

off1_ni

EpicsSignal

:OFF1_NI

config

off2_i

EpicsSignal

:OFF2_I

config

off2_ni

EpicsSignal

:OFF2_NI

config

off3_i

EpicsSignal

:OFF3_I

config

off3_ni

EpicsSignal

:OFF3_NI

config

out

EpicsSignal

:OUT

normal

rawdata

EpicsSignal

:RAWDATA

normal

train

EpicsSignal

:TRAIN

config

trig_delay

EpicsSignal

:TRIG_DELAY

config

trig_event

EpicsSignal

:TRIG_EVENT

config

Methods

configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]

Configure the device for something during a run

This default implementation allows the user to change any of the configuration_attrs. Subclasses might override this to perform additional input validation, cleanup, etc.

Parameters:

d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.

Returns:

  • (old, new) tuple of dictionaries

  • Where old and new are pre- and post-configure configuration states.

describe() OrderedDictType[str, Dict[str, Any]]

Provide schema and meta-data for read().

This keys in the OrderedDict this method returns must match the keys in the OrderedDict return by read().

This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.

Returns:

data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the event_model.event_descriptor.data_key schema.

get(**kwargs)

Get the value of all components in the device

Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.

post_elog_status()

Post device status to the primary elog, if possible.

read() OrderedDictType[str, Dict[str, Any]]

Read data from the device.

This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in trigger().

The OrderedDict returned by this method must have identical keys (in the same order) as the OrderedDict returned by describe().

By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in bluesky.

The values in the ordered dictionary must be dict (-likes) with the keys {'value', 'timestamp'}. The 'value' may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.

Returns:

data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys {'value', 'timestamp'}

read_configuration() OrderedDictType[str, Dict[str, Any]]

Dictionary mapping names to value dicts with keys: value, timestamp

To control which fields are included, change the Component kinds on the device, or modify the configuration_attrs list.

screen()

Open a screen for controlling the device.

Default behavior is the typhos screen, but this method can be overridden for more specialized screens.

status() str

Returns a str with the current pv values for the device.

stop(*, success=False)

Stop the Device and all (instantiated) subdevices

summary()
trigger() StatusBase

Trigger the device and return status object.

This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.

If there is an appreciable time between triggering the device and it being able to be read (via the read() method) then this method is also responsible for arranging that the StatusBase object returned by this method is notified when the device is ready to be read.

If there is no delay between triggering and being readable, then this method must return a StatusBase object which is already completed.

Returns:

status (StatusBase) – StatusBase object which will be marked as complete when the device is ready to be read.

Attributes

configuration_attrs
connected
hints
kind
subscriptions: ClassVar[FrozenSet[str]] = frozenset({'acq_done'})