pcdsdevices.qadc.Qadc134Lcls2
- class pcdsdevices.qadc.Qadc134Lcls2(*args, **kwargs)
Class for LCLS-2 FMC134 digitizers. Implements LCLS-2 timing interface.
Attribute
Class
Suffix
Docs
Kind
Notes
trig_rate_mode
EpicsSignal
:TRIG_RATEMODE
LCLS-II trigger mode
config
Inherited from
QadcLcls2Timing
trig_fixed_rate
EpicsSignal
:TRIG_FIXEDRATE
Rate to use for fixed trigger mode
config
Inherited from
QadcLcls2Timing
trig_ac_rate
EpicsSignal
:TRIG_ACRATE
Rate to use for AC trigger mode
config
Inherited from
QadcLcls2Timing
trig_ts_mask
EpicsSignal
:TRIG_TSMASK
Trigger mask
config
Inherited from
QadcLcls2Timing
trig_seq_num
EpicsSignal
:TRIG_SEQNUM
Trigger sequence number
config
Inherited from
QadcLcls2Timing
trig_seq_bit
EpicsSignal
:TRIG_SEQBIT
Trigger sequence bit
config
Inherited from
QadcLcls2Timing
trig_partition
EpicsSignal
:TRIG_PARTITION
Trigger partition number
config
Inherited from
QadcLcls2Timing
ch0
EpicsSignal
:CH0
Input 0 of the ADC
normal
Inherited from
Qadc134Common
ch1
EpicsSignal
:CH1
Input 1 of the ADC
normal
Inherited from
Qadc134Common
ch2
EpicsSignal
:CH2
Input 2 of the ADC
normal
Inherited from
Qadc134Common
ch3
EpicsSignal
:CH3
Input 3 of the ADC
normal
Inherited from
Qadc134Common
config
EpicsSignal
:CONFIG
Write the current config to the QADC
config
Inherited from
Qadc134Common
start
EpicsSignal
:START
Start/stop acquisition
normal
Inherited from
Qadc134Common
trig_delay
EpicsSignal
:TRIG_DELAY_RBV
Trigger delay in EVR/TPR ticks
config
Inherited from
Qadc134Common
full_en
EpicsSignal
:FULL_EN_RBV
Enable full stream
config
Inherited from
Qadc134Common
hi_thresh
EpicsSignal
:HI_THRESH_RBV
High threshold, in Volts
config
Inherited from
Qadc134Common
hi_thresh_raw
EpicsSignal
:HI_THRESH_RAW_RBV
High threshold, raw
config
Inherited from
Qadc134Common
ichan
EpicsSignal
:ICHAN_RBV
Channel to interleave on
config
Inherited from
Qadc134Common
interleave
EpicsSignal
:INTERLEAVE_RBV
Interleave enabled?
config
Inherited from
Qadc134Common
length
EpicsSignal
:LENGTH_RBV
Waveform length
config
Inherited from
Qadc134Common
lo_thresh
EpicsSignal
:LO_THRESH_RBV
Low threshold, in Volts
config
Inherited from
Qadc134Common
lo_thresh_raw
EpicsSignal
:LO_THRESH_RAW_RBV
Low threshold, raw
config
Inherited from
Qadc134Common
prescale
EpicsSignal
:PRESCALE_RBV
Trigger prescale divider
config
Inherited from
Qadc134Common
rows_after
EpicsSignal
:ROWS_AFTER_RBV
config
Inherited from
Qadc134Common
rows_before
EpicsSignal
:ROWS_BEFORE_RBV
config
Inherited from
Qadc134Common
sparse_en
EpicsSignal
:SPARSE_EN_RBV
Enable sparsified mode
config
Inherited from
Qadc134Common
clear_config
EpicsSignal
:CLEAR_CONFIG
Clear the current configuration
config
Inherited from
Qadc134Common
out0
EpicsSignal
:OUT0
Full output zero
normal
Inherited from
Qadc134Common
out1
EpicsSignal
:OUT1
Full output one
normal
Inherited from
Qadc134Common
rawdata0
EpicsSignal
:RAWDATA0
Raw output zero
normal
Inherited from
Qadc134Common
rawdata1
EpicsSignal
:RAWDATA1
Raw output one
normal
Inherited from
Qadc134Common
sparse0
EpicsSignal
:SPARSE0
Sparsified output zero
normal
Inherited from
Qadc134Common
sparse1
EpicsSignal
:SPARSE1
Sparsified output one
normal
Inherited from
Qadc134Common
Methods
- configure(d: Dict[str, Any]) Tuple[Dict[str, Any], Dict[str, Any]]
Configure the device for something during a run
This default implementation allows the user to change any of the
configuration_attrs
. Subclasses might override this to perform additional input validation, cleanup, etc.- Parameters:
d (dict) – The configuration dictionary. To specify the order that the changes should be made, use an OrderedDict.
- Returns:
(old, new) tuple of dictionaries
Where old and new are pre- and post-configure configuration states.
- describe() OrderedDictType[str, Dict[str, Any]]
Provide schema and meta-data for
read()
.This keys in the
OrderedDict
this method returns must match the keys in theOrderedDict
return byread()
.This provides schema related information, (ex shape, dtype), the source (ex PV name), and if available, units, limits, precision etc.
- Returns:
data_keys (OrderedDict) – The keys must be strings and the values must be dict-like with the
event_model.event_descriptor.data_key
schema.
- get(**kwargs)
Get the value of all components in the device
Keyword arguments are passed onto each signal.get(). Components beginning with an underscore will not be included.
- post_elog_status()
Post device status to the primary elog, if possible.
- read() OrderedDictType[str, Dict[str, Any]]
Read data from the device.
This method is expected to be as instantaneous as possible, with any substantial acquisition time taken care of in
trigger()
.The
OrderedDict
returned by this method must have identical keys (in the same order) as theOrderedDict
returned bydescribe()
.By convention, the first key in the return is the ‘primary’ key and maybe used by heuristics in
bluesky
.The values in the ordered dictionary must be dict (-likes) with the keys
{'value', 'timestamp'}
. The'value'
may have any type, the timestamp must be a float UNIX epoch timestamp in UTC.- Returns:
data (OrderedDict) – The keys must be strings and the values must be dict-like with the keys
{'value', 'timestamp'}
- read_configuration() OrderedDictType[str, Dict[str, Any]]
Dictionary mapping names to value dicts with keys: value, timestamp
To control which fields are included, change the Component kinds on the device, or modify the
configuration_attrs
list.
- screen()
Open a screen for controlling the device.
Default behavior is the typhos screen, but this method can be overridden for more specialized screens.
- stop(*, success=False)
Stop the Device and all (instantiated) subdevices
- summary()
- trigger() StatusBase
Trigger the device and return status object.
This method is responsible for implementing ‘trigger’ or ‘acquire’ functionality of this device.
If there is an appreciable time between triggering the device and it being able to be read (via the
read()
method) then this method is also responsible for arranging that theStatusBase
object returned by this method is notified when the device is ready to be read.If there is no delay between triggering and being readable, then this method must return a
StatusBase
object which is already completed.- Returns:
status (StatusBase) –
StatusBase
object which will be marked as complete when the device is ready to be read.
Attributes
- configuration_attrs
- connected
- hints
- kind